Program mode:
Pump with pressure
transducer
Complete Step through Step
(page and page ) of pump
with pressure switch.
Step
Display
Press
P
: Programs setting of where internal
pressure transducer will close. This is the
maximum pressure that pump can reach.
Factory setting is psi
(241 bar)
.
• Press button to change value
Reading x = Transducer setting in psi
x = psi
Setting is adjustable from
to psi
(97 to 317 bar)
in
psi
(7 bar)
increments.
NOTE
P
only appears if pump has internal
pressure transducer.
Step
Display
Press
P
: Programs setting of where external
pressure transducer will open. Opening point
(vent pressure) is adjustable from
to psi
(14 to 69 bar)
in
psi
(6,9 bar)
increments. Factory set
opening point (vent pressure) is
psi
(62 bar)
. Closing point of external
pressure transducer is fixed in software at
psi
(172 bar)
.
• Press button to change value
Reading x = Transducer setting in psi
x = psi
(62 bar)
NOTE
P
only appears if pump has external
pressure transducer connected.
Complete program
Press button.
P –
is displayed.
NOTE
Program must be completed to save
new values.
Step
Display
Press
• Press key (
additional lubrication
) to
complete programming and save
entered parameters.
Program mode of pump with pressure
transducer is complete.
NOTE
Press key
additional lubrication
within
seconds to save changed parameters.
After seconds, program reverts to
previous settings.
Important: Recheck parameter
settings in operating mode after
programming is complete.