Table
Factory settings
Programming steps
Factory setting
Description
Count
Thousands, hundreds
Count
Tens, unit
NO
Output of both fault relays
no
(normally open)
nc
(normally closed)
o
Two options for signaling a fault
o (Option )
F relay contact
a) Low–level fault will cause
F
contact to repeatedly open and close.
b) Pressure fault will cause
F
contact to close and stay closed.
F
relay contact
A low–level fault or a pressure fault will cause the
F
contact to close and stay closed.
o (Option )
F
fault relay’s contact will close on a low–level fault
F
fault relay’s contact will close on a pressure fault
Both of these contacts can be used for remote signaling.
The
P
programming step will only appear if you have a pump that uses an internal pressure transducer.
(Reading x )
x = psi
(241 bar)
. psi
(241 bar)
is the maximum pressure that the pump will build.
Adjustable from to psi
(96 to 317 bar)
in psi
(6.9 bar)
increments.
The
P
programming step will only appear if you have a pump that uses an external pressure transducer.
(Reading x )
x = psi.
(62 bar)
psi.
(62 bar)
is where the external pressure transducer will open (
vent
)
adjustable from to psi
(13.7 to 68.9 bar
) in psi
(6.9 bar)
increments.