background image

1

Foundation according 

(to the structural calculations, not included in the scope of delivery):

 

concrete C25/30, 

strip foun-

dation:

 w/h = 30/90cm, each 2 Ø 12 top and bottom, bow Ø 6, e < 20cm. 

Bottom panel: 

t=14cm,Q188A, top and bottom

throughout. Anchoring of the floor beams on the strip foundation using bolts M12, e < 60cm (by customer).

Before the side planks are screwed together, it is imperative that the following is observed:

 The position of the wall in

which the bolting is done must 

definitely be correct

 / the planks to be joined must be firmly pressed together before final

bolting.

The thread rods to secure the house against storm are secured at the top with a washer and a nut, from below with a wa-

sher, spring and nut to tighten the upper nut of the thread rod without any problem, the spring at the bottom should be

pressed upwards with the thread rod. 

The spring may only be tightened slightly 

so that the house can work at the top. The

projecting ends of the thread rods have to be cut off at the top

. Even after the house has been completed, attention must

always be paid to the fact that the thread rods are not seated on the floor as otherwise when it is dry, gaps can arise and the

roof is pressed upwards. The thread rods can also be pushed subsequently into the bores. You have to make sure that 

each

plank has a bore

 and that these are free and 

not blocked by shavings or similar

.

In case of varying weather conditions, the wood alters in height (due to 'working'). To avoid the formation of joints, the planks

of the house may not, for example, be joined 

to one another through several block planks 

as then the wood can no longer

expand.

The 

door and the window frames or their respective edging boards

 must not be 

fastened to the wall planks

. If the door

cannot be closed properly

, this can be adjusted by 

turning the hinges

.

According to the static calculations a solid connection between the posts (for projecting roof) and ground is absolutely ne-

cessary. Screw-in supports as well as post anchors for casting into concrete are statically permissible. Drive-in sleeves are

not approved. Assembly with screw-in supports is described in the set-up instructions. 

This is only a recommendation.

 See

manufacturer's instructions regarding mounting hardware for posts and foundations (bolts). Every construction site and each

construction element exhibits different settling characteristics. Please note that we cannot take this into consideration in our

planning and therefore cannot assume any liability for this factor. Die columns are supplied longer and must be shortened to

the desired length by the customer.

The sealing in the eaves area (block planks/roof boarding) must be provided 

by the customer

. Suggestion without obliga-

tion: Use a permanently plastic jointing compound and a 1/4 strip for as sealing.

-

-

-

-

-

-

-

1

2

3

4

5

To the drawings:

6

© SKAN HOLZ Europe GmbH D-21227 Bendestorf. Technical modifications reserved. All dimensions are approximate dimensions. Date 06/18

7

Ontario 600 x 500cm

621903

621910

621927

Important information for your wood panel cabin

We are pleased that you have chosen a product of SKAN HOLZ.

Please check the construction set for completeness using the position list in good time before starting construction or

commissioning your construction team. 

If individual parts are defective or missing, we will deliver these as quickly as possible.

However, we cannot refund the costs for any resulting construction delays to a construction company.

Please understand that we cannot assume any guarantee fort he following defects:

- incorrect storage before assembly

- incorrect anchoring with the ground or inadequate foundation (foundation according to statics)

- damage due to erection errors, e. g. the house is not level or not right-angled

- damage through a higher level of snow burden than statically envisaged.  Recommendation: lad relief of the roof by remo-

  ving the snow layer

- storm damage (insurance cases) or violent destruction

- damage through any alteration to the design by the client

- natural formation of cracks, branch holes, twisting,  decolouration or similar modification (natural process; has no influence

  on the statics)

Storage tips before assembly:

- store pallet on a level and dry surface. Tip: do not remove the foil and steel strapping until just before assembly!

- protect against sunshine and dampness; wood can warp drastically in a loose condition!

Maintenance tips:

  

The wood is untreated. Accordingly, regular, protective coating is absolutely necessary!

  Please observe the attached information sheet “Care instructions/Colour treatment”.

General tips and refers to:

General:

-

 Windows and outside doors are supplied with insulating glass. Any additional insulation must be installed 

by the customer

.

- The floor can be insulated 

by the customer

. Please obtain relevant information from a specialist.

- Recommendation:

 predrill all screw holes!

- Regarding basic construction set:

 

Given that the roof is constantly exposed to the weather, a covering with only one

layer of roofing paper will not be enough over the long-term. An additional covering

with bitumen shingles, alternatively with a material of at least equivalent quality, 

must follow.

- for tile roofing:

 

a standard dimension for tile roofing was determined for calculating the roof lathing.

- Any optional roof insulation (in case of shingling and tile roofing) must be provided 

by the customer

; please obtain relevant

  information from a specialist. 

Shingles and tiles are not included in delivery.

Summary of Contents for 621903

Page 1: ...aves area block planks roof boarding must be provided by the customer Suggestion without obliga tion Use a permanently plastic jointing compound and a 1 4 strip for as sealing 1 2 3 4 5 To the drawing...

Page 2: ...le client L tanch it du larmier poutres plafonnage du toit doit tre r alis e par le client Conseil indicatif effectuer l tanch it l aide d un produit appropri une p te joint d lasticit permanente et d...

Page 3: ...t een ander inklinkingsgedrag Houd er rekening mee dat wij dit in onze planningen niet kunnen meeberekenen en dat we daarom geen aansprakelijkheid kunnen aanvaarden voor dit onderdeel De palen worden...

Page 4: ...iivisteet estopaalut kattopeite on asennettava paikan p ll Ei sitova ehdotus Tiivistys sopivalla kestoe lastisella sekoitustiivisteell ja 1 4 kaistaleliuskalla 1 2 3 4 5 6 7 Piirustukseen Yleisi neuvo...

Page 5: ...nicht richtig schlie en lassen kann dieses durch Drehen der Scharniere justiert werden Gem Statik ist eine feste Verbindung von den Pfosten f r Vordach zum Boden unbedingt notwendig Aufschraubst tzen...

Page 6: ...6 x 87 5cm 4 x 199 5cm 2 x 202 5cm 5 x B440 250 1 x 70 ETL 02 2 x 70 DF 02 120 x 139cm 120 x 175cm 30 x 392cm 1 x 499cm 16 x 300cm 20 x 140cm 4 x 329cm 4 x 340cm 4 x 340cm 1 x B440 310 43 x 185cm 1 23...

Page 7: ...4 x 199 5cm 2 x 202 5cm 1 x 70 ETL 02 2 x 70 DF 02 124 x 139cm 124 x 175cm 1 x 499cm 16 x 300cm 20 x 140cm 4 x 339cm 4 x 340cm 43 x 185cm 1 235cm 2 238cm 3 231cm 4 235cm 5 238cm 6 235cm 7 445cm 8 442...

Page 8: ...5cm 1 x 70 ETL 02 2 x 70 DF 02 1 235cm 2 238cm 3 231cm 4 235cm 5 238cm 6 235cm 7 445cm 8 442cm 9 449cm 10 445cm 11 442cm 12 445cm 1 2 x 70 IT 05 2 x 124 x 139cm 124 x 175cm 1 x 499cm 16 x 300cm 20 x...

Page 9: ...Beginnen Sie mit ffnen des Paketes Blockbohlen Grundlager allg Zubeh r Bei den Blockbohlen ffnen Sie zuerst Paket 1 dann Paket 2 Start by opening the package Block planks ground supports general Acce...

Page 10: ...18 600 x 500cm 621903 621910 621927 4 2 2 4 x 2 3 2 2 B105 140 140mm 3 3 2 3 2 2 x B105 140 140mm 2 1 5mm 2 2 2 4 B105 100 100mm 2 1 B105 140 140mm a 2 3 B105 150 150mm 3 1 a 2 a B105 4mm 2 5 x 86cm 3...

Page 11: ...0mm B105 100 100mm 82 5cm 87 5cm 82 5cm A 87 5cm B 199 5cm C 2 x 82 5cm A 2 x 82 5cm A 2 x 202 5cm D 1 2 6 x B104 090 90mm 202 5cm D 2 x 199 5cm C 2 x 199 5cm C 2 x 87 5cm B 2 x 87 5cm B 2 x 87 5cm B...

Page 12: ...5 2 5 3 B105 120 120mm 4mm B440 250 2 3 4 5 6 5 5 a b 2 x B105 150 150mm 2 x B105 150 150mm a b a b Montagebeispiel for example Example de montage Montagevoorbeeld Asennusesimerkki B440 250 B105 150...

Page 13: ...B105 080 80mm 180cm 7 x B105 080 80mm B105 100 100mm 4mm B105 080 80mm 5 x B105 120 120mm 1 2 7 1 10 x B105 120 120mm B105 120 120mm 4mm 7 1 B105 120 120mm 2 0 2 0 2 0 3 3 B105 120 120mm 7 2 30 30 Nut...

Page 14: ...chraubung wie bei Mittelpfetten Bolting as for centre pulins Vissage comme pour les fa ti re moyennes Vastschroeven zoals bij middelste gordingen Ruuvaus kuten keskiorhissa 4 x B105 150 150mm B430 310...

Page 15: ...060 60mm 175cm 2 x B105 060 bzw 60mm 9 4 175cm 5 x B105 060 60mm 9 2 9 1 B105 060 60mm B105 060 60mm 120 200cm 3 5 x B105 030 30mm nur bei 621903 only for 621903 uniquement pour 621903 alleen bij 621...

Page 16: ...2 8 14cm 7 x B105 080 80mm 10 1 10 3 10 1 B501 4 c m B501 120 200cm 140cm 4 x B105 030 30mm 140cm 4 x B105 030 30mm 340cm 1 6 5 8cm 7 x B105 040 40mm 340cm 1 6 5 8cm 7 x B105 040 40mm 10 2 A100 220N 3...

Page 17: ...100 100mm 140cm 4 x B105 030 30mm 140cm 4 x B105 030 30mm 10 10 3 10 1 10 2 10 3 388 292 388cm 2 8 14cm 5 x B105 080 80mm 140cm 4 x B105 030 30mm 319 5cm 1 9 4cm 6 x B105 040 40mm 319 5cm 4 3 12cm 3...

Page 18: ...m 292cm 388cm 10 5 B105 100 100mm B105 100 100mm 10 3 10 6 319 5cm 1 9 4cm 6 x B105 040 40mm 10 2 10 1 B105 200 200mm 4mm 4mm B105 200 200mm 319 5cm 319 5cm 10 1 10 2 10 5 300 388 292 319 5cm 1 9 4cm...

Page 19: ...9cm 2 8 7cm 336cm 2 8 14cm 292 388cm 2 8 7cm 10a 2 10a 1 3 336cm 2 8 14cm 7 x B105 080 80mm 339cm 2 8 14cm 7 x B105 080 80mm 388cm 2 8 14cm 5 x B105 080 80mm 388cm 2 8 7cm 5 x B105 080 80mm 292cm 2 8...

Page 20: ...mbH D 21227 Bendestorf Stand 06 18 f r for pour voor varten 621927 309979 309962 309955 2 1 1 1 3 4 1 1 C117 4x 2 1 1 2 3 1 3 2 2 1 3 1 3 2 4 1 4 1 C117 4x C117 4x 1 c m Zus tzlich Additional En plus...

Page 21: ...06 18 600 x 500cm 11 11 1 621903 621910 621927 11 185cm 8 x B105 050 50mm 50cm 40mm X Fu leisten Skirting boards Lambris Plinten Jalkalistat 11 1 X X X X 392cm 14 x B105 050 50mm 5mm 185 392cm 2 x B1...

Page 22: ...r frame on the floor de pending on the opening side 2 Screw hinges to the frame and to the door 3 Remove the key from door lock 4 Mount the door into door frame 5 Make sure that the lock is in correct...

Page 23: ......

Page 24: ...n regelm iger Pflegeanstrich ist erforderlich Achten Sie in jedem Fall auf einen guten UV Schutz der Produkte sowie die Verarbeitungsrichtlinien des Lasurherstellers Spezielle Pflegehinweise zu farbli...

Page 25: ...th a high quality wood preserving varnish Regular varnishing is necessary to maintain the wood Make sure the products are given good UV protection and that the working guidelines of the varnish manufa...

Page 26: ...en r guli re est essentielle Dans tous les cas veillez assurer une bonne protection UV des produits et respectez les directives d application du fabricant de lasure Consignes d entretien sp ciales pou...

Page 27: ...ut Een regelmatige verzorgende coating is vereist Zorg in ieder geval voor een goede UV bescherming van de producten en volg de richtlijnen van de fabrikant voor de verwerking van de lazuurverf Specia...

Page 28: ...ojaavaa laadukasta kuultomaalia S nn llinen suojamaalaus on v ltt m t nt Varmista aina ett maalissa on hyv UV suoja ja noudata valmistajan ohjeita Erityishuolto ohjeet SKAN HOLZin maalipintaisille tuo...