7- SET KEY
It select working procedure.
Press it for 3 seconds to enter in MENU.
During the navigation in MENU give the
possibility to move on the right.
8- KEY
“-“
It select binding type.
During the navigation in MENU give the
possibility to move down.
9- KEY
“+”
It select binding type.
During the navigation in MENU give the
possibility to move up.
5.9.3 Programming
Carry out programming operations in order to
modify the buzzer volume or select the type of
binder on the baler.
Press SET key for 3 seconds to enter in MENU.
Once in MENU it is possible to modify the
statement using MODE, SET, “-“, “+” keys.
Hereafter it has been reproduced MENU map:
MENU
BUZZER
1
2
3
4
WRAP
TWINE
NET
BOTH
Buzzer volume can be settled between following
values: 1 (minimum) and 4 (maximum).
Use entry WRAP to settle binder type on the
baler:
TWINE: there is only twine binding
NET: there is only net binding
BOTH: the baler have both twine and net binding.
5.9.4 Manual use
1) Switch on control device (C)
If display doesn’t switch on verify feeding
polarity and fuse entireness.
2) With MODE or SET keys select MAN working
procedure.
3)
With “-“ and “+” keys select binding type (twine
or net).
4) With COUNTER key select partial counter type
(carry out eventually zero setting).
5) Verify STOP LED.
It has switched on when rear d
oor hooks aren’t
closed or guillotine of net binding hasn’t been
armed.
In this case try to control rear door closing or,
eventually, open completely rear door and shut
it again.
When STOP LED switches off, the baler is
ready to begin product collection.
6) C
ollection’s begin.
7) When the chamber gets to the settled
pressure, the buzzer starts to utter its sound
and STOP LED switches on.
Press START key and keep it pressed till twine
or net won’t have caught (in this case can be
seen a rise of the rotation speedy of twine
pulley or of net roll).
8) Binding end has signalled by the buzzer with 3
sounds, each of which lasts 1 second, and by
STOP LED, which starts to flash.
9) Open the rear door to discharge bale.
During this operation the partial counter,
displayed together with the total one, has
raised.
5.9.5 Semi-automatic use
Follow the same procedure described in manual
working with the following differences:
Point 2): Select SAT working.
Point 7): When the chamber gets to the settled
pressure, the buzzer starts to utter its sound and
STOP LED switches on.
Press shortly START key.
Buzzer will utter the last sound, that will last 1
second, and control device will keep feeding of
binder motor for 10 seconds. Usually this time
is sufficient to guarantee the entry of twines or
net inside of pick-
up. In case this won’t be it is
possible to press again START key.
It is possible anytime to interrupt the motor’s
feeding selecting manual procedure with SET or
MODE keys.
5.9.6 Automatic use
Follow the same procedure described in manual
working with the following differences:
Point 2): Select AUTO working.
Point 7): When pick-up gets to the settled
pressure, the buzzer utters 1 second and STOP
LED switches on.
Control device will keep feeding of binder
motor for 10 seconds. Usually this time is
sufficient to guarantee the entry of twines or
net inside of pick-
up. In case this won’t be it is
possible to press again START key.
Pressing START key it is possible to start binding
before the pick-up gets to the settled pressure.
It is possible anytim
e to interrupt the motor’s
feeding selecting manual procedure with SET or
MODE keys.