![sitrex Action 120 Use And Maintenance Manual Download Page 26](http://html.mh-extra.com/html/sitrex/action-120/action-120_use-and-maintenance-manual_1285841026.webp)
Round Baler ACTION 120
USE AND MAINTENANCE MANUAL - 26 -
The main components of the machine's hydraulic
system are:
A -
Rear door opening cylinders;
B -
Pick-up lifting cylinder;
C -
Transmission clutch cylinder.
DANGER
It is strictly forbidden to tamper with the
above-mentioned throttle valve, under any
circumstances. When in doubt, contact the
Manufacturer’s Service Centre.
DANGER
The specified maximum pressure of 210 bar of
the hydraulic oil must never be exceeded. A
value higher of the hydraulic oil can damage
the machine.
The hydraulic system is filled with AGIP
SUPER TRACTOR UNIVERSAL 15W40 oil.
The lever of the tractor’s hydraulic system
distributor must be secured in the “open” position
(hydraulic oil circulating).
The flexible pipes of pick-up lifting, opening rear
door and tension harm must be tied using female
plugging of ½” installed on tractor. On the pick-up
flexpipe is installed a tap of blocking that must be:
OPENED: with the baler in working
CLOSED: with the pick-up lifted in
transport position or in transport case.
WARNING
Before to do operation under the pick-up
lifted, close the tap and avoid the lowering
with a proper support.
The hydraulic flexpipe are marked with the
indications of:
-
Manufacturer code
-
Date of production
-
Maximum operating pressure
WARNING
Replace the hydraulic pipes if they appear
damaged, or every 5 years of operation
5.6 ELECTRIC SYSTEM
The round baler is equipped with a lighting
system. The tractor must therefore be equipped
with a 7-pin socket in which to insert the plug of
the round baler lights. It is also necessary to
install a 12V socket on the tractor (connected to
the battery and supplied with the control unit), for
powering the control unit.
WARNING
Periodically it is necessary to control the
lights and if it necessary replace them.
5.7 ELECTRIC SIGNAL OF FINAL
DENSITY OF PRESSING
“M50”
Using the bracket fit the warning unit on the
tractor within the driver’s field of view and connect
it with the relevant socket on the round baler by
means of the cable. The second cable must be
connected to the tractor’s power supply (12 V).
As soon as the round bale has reached the
desired pressing density (see “Adjusting the round
bale density”), a buzzer sounds and the red light
comes on. The bale is therefore ready to be
bound.
As soon as the light comes on/warning sounds, it
is advisable to start binding (Pic. 12A):
1- STOP LIGHT FULL CHAMBER
2- FEEDING LIGHT SWITCH BOARD