7
Eco3
16" Tray
16" Tray
Gas Group
G20 Natural Gas CAT I2H Propane (G31)
Inlet Pressure
20 mbar
36 mbar
Max Input (gross)
6.9
5.9
Min Input (gross)
2.4
2.5
Setting Pressure
20 mbar
36 mbar
Gas Inlet connection
8mm Compression
8mm Compression
Overall Height
N/A
N/A
Overall Width
382
382
Overall Depth
196
196
Recess back width
265
265
Tray Height
210
210
Recess Depth
171
171
Air Vent
N/A
N/A
Injector
STEREOMATIC 480
STEROMATIC 190
Valve
CPMM 18700/357
CPMM 18700/357
Manual
Pilot Assembly &
Thermocouple
Thermocouple
T100/1332 250
Thermocouple T100/1332
250