Fig. 18
Fig. 19
Fig. 19
3.2.7. Installation of the Xroom unit on the wall
-
Bolt the removed installation pins back into the installation templates nuts and tighten them with an 8
mm wrench.
-
During the entire handling of the unit from the box on the assembly template, work with caution to
avoid damage to the sealed connections between the piping and the unit.
-
From box 1 – “Xroom unit”, remove the unit (black fitting) with the installed piping so that the front metal
cover, which is located at the bottom of the package, still remained in the box, or use the cut box and
slide the unit to the side; however, the metal front cover must remain in the box.
-
Close box 1 – “Xroom unit” with the front metal cover and place it in a safe place outside the assembly
area to prevent damage or dusting of the front cover.
3.2.8. Xroom Unit Final Fitting
-
Partly slide the removed unit onto the installation template pins.
-
Connect the ground wire connector to the grounding point of the installationtemplate to achieve a
connection between the grounding of the unit and the installation template to ensure correct electrical
safety of the unit.
3.2.8.1.
Electric heater variant (XR1-010-ECE1...), without heating – cold (XR1-010-ECS0...)
-
Press the rear wall of the unit towards the installation template and secure the unit with the supplied
M6x25 bolts (part of the delivery, in a bag) into the installation pins.
TIGHTEN WITH THE WRENCH 8
FIT THE UNIT ON THE INSTALLATION PINS +
SLIDE ALREADY GLUED PIPING INTO THE
HOLES DRILLED IN THE WALL.
1
PARTIALLY FIT THE UNIT ON THE BOLTED PINS
AND CONNECT THE EARTHING CABLE TO THE
PREPARED EARTHING CONNECTOR ON THE
BOARD.
2
Fig. 20
29
Version 1 – GBR(23/06/2021)
D-502-0152