N/B Maintenance
N/B Maintenance
1.8 Power Specification
+1.2VLDTA: Main Power Source that turns off in S3
+NB_CORE: Main Power Source that turn off in S3
+3V: Main Power Source that exist only the system is power on
+3VS: Main Power Source that turns off in S3
+5V: Main Power Source that exist only the system is power on
+5VS: Main Power Source that turns off in S3
VDD3: Auxiliary power that exist regardless the system is power down or power up
VDD5: Auxiliary power that exist regardless the system is power down or power up
+1.8VS: Main Power Source that turn off in S3
+2.5V: Main Power Source that provides 1.25V for the termination of the signal of DDR
+1.25V: Main Power Source that provides 1.25V for the termination of the signal of DDR
+1.25VS: Main Power Source that turns off in S3
+VCC_CORE: Main Power Source it can match AMD MOBILE K8