![Sinty Zhang 8317 Service Manual Download Page 120](http://html1.mh-extra.com/html/sinty-zhang/8317/8317_service-manual_1283311120.webp)
119
8317
8317
N/B Maintenance
N/B Maintenance
Display
OK?
Replace faulty
LCD.
Display
OK?
VGA Controller Test Error
LCD No Display
1. Confirm LCD panel or monitor is good
and check the cable are connected
properly.
2. Try another known good LCD module.
Remove all the I/O device & cable from
motherboard except LCD panel or
extended monitor.
Connect the I/O device & cable to
the M/B one at a time to find out
which part is causing the problem.
Yes
No
Yes
No
Re-soldering.
One of the following parts on the mother-board may be
defective, use an oscilloscope to check the following signal or
replace the parts one at a time and test after each replacement.
Parts:
Signals:
Board-level
Troubleshooting
Replace
Motherboard
Yes
No
U1005
U1025
J2
J3
U7
SF1
FB5
FB6
D1008
D1009
+3VS
NB_PWRGD
LCD_DIGON
TXOUT[10,11,12,20,21,22]+
TXOUT[10,11,12,20,21,22]-
TXCLKOUT[1,2]+
TXCLKOUT[1,2]-
ENABKL_VGA
ENPBLT_NB
LID_SW#
BLADJ
8.3 VGA Controller Test Error LCD No Display(2)
There is no display or picture abnormal on LCD although power-on-self-test is passed.
Check if
J2, J3 are cold
solder?