AIR-TO-WATER HEAT PUMP INSTALLATION MANUAL
Quick water heating:
in quick water heating mode, the unit runs according to the
water heating control of heat pump and the e-heater of water tank runs at the same time
;
Forced Operation Mode:
this mode is only used for refrigerant recovery and
debugging for the unit
;
Holiday mode:
this mode is only available for heating mode. This mode is set to keep
indoor temperature or leaving water temperature in a certain range, so as to prevent water
system of the unit from freezing or protect certain indoor articles from freezing damage. When
the outdoor unit stops due to malfunction, the two e-heaters of the unit will run.
Disinfection mode:
i
n this mode, the water heating system can be disinfected. When
starting up the disinfection function and setting corresponding time to meet the requirement of
disinfection mode, the function will start. After the setting temperature is reached, this mode
will terminate.
Weather-dependent Operation:
this mode is only available for space heating. In
Weather-dependent
mode, the setting value
(
remote room air temperature or leaving water
temperature
)
is detected and controlled automatically when the outdoor air temperature is
changed.
Silent mode:
Silent mode is available in cooling, heating and water heating mode. In
silent mode, the outdoor unit will reduce the running noise via automatic control.