23/13
2
3
Red
Brown
Green/Yellow
2
3
PE
①
Position the declutching lever.
②
Position the wire-strainer on the cable.
③
Position the wire-strainer into the declutching lever.
④
Tighten the declutching cable by hand until resistance is felt without declutching the motor.
⑤
Tighten the M4 screws from cable clamp to couple 3 Nm.
⑥
Having achieved 3 declutching, take up the play created using the nuts of the wire-strainer, still without
declutching the motor.
⑦
Cut the declutching cable to 2cm of from the wire-strainer.
i
If necessary, it is possible to tighten the declutching cable reproducing step
⑥.
4.3 Mounting of the declutching
- Clip the switch on its bracket.
CAUTION: Do not pinch or damage wires.
- Screw the bracket to the box with 2 screws provided for this purpose to a
torque of 2 Nm.
b- with SIMU control boxes
SIMU
CONTROL
BOX
for connection and setting refer to the instructions of the SIMU control box.
i
Connect the power cables on the switch.
CENTRIS MOTOR
②
③
①
②
③
④
⑤
⑥
⑦