Electrical continuity must be ensured along the entire length of
all cable coverings, particularly at joints and splices. In no case
should the shielding of cables be used as the only means of
grounding cables or units.
Metallic casings, pipes and conduits must be grounded, and
when fitted with joints these must be mechanically and
electrically grounded locally.
Cable connections
All cable connections are shown on the applicable cable plan
and interconnection diagrams.
Where the cable plan shows cable connections outside an
equipment box outline, the connections are to be made to a plug
or socket which matches the plug or socket on that particular
item of equipment.
Where two cables are connected in series via a junction box or
terminal block, the screens of both cables must be connected
together but not grounded.
Cable terminations
Care must be taken to ensure that the correct terminations are
used for all cable conductors, especially those that are to be
connected to terminal blocks. In this case, crimped
sleeve-terminations must be fitted to prevent the conductor core
from fraying and making a bad connection with the terminal
block. It is also of the utmost importance that where crimped
terminations are used, the correct size of crimp and crimping
tool are used. In addition, each cable conductor must have a
minimum of 15 cm slack (service loop) left before its
termination is fitted.
Cable identification
Cable identification codes corresponding to the cable number
shown in the cable plan must be attached to each of the external
cables. These identification codes should be positioned on the
cable in such a way that they are readily visible after all panels
have been fitted. In addition, each cable conductor should be
marked with the terminal board number or socket to which it is
connected.
Summary of Contents for SP90 - REV E
Page 2: ......
Page 12: ...Simrad SP90 VIII 851 164510 Rev E...
Page 62: ...Simrad SP90 50 851 164510 Rev E Figure 10 Mounting the Transceiver Unit CD3110A...
Page 75: ...Cable layout 63 851 164510 Rev E Figure 15 SP90 Cable plan...
Page 214: ...Simrad SP90 202 851 164510 Rev E SP90 Sonar Operating Panel Outline dimensions...
Page 215: ...Drawing file 203 851 164510 Rev E SP90 Sonar Processing Unit MC70 Outline dimensions...
Page 216: ...Simrad SP90 204 851 164510 Rev E SP90 Sonar Interface Unit Outline dimensions...
Page 217: ...Drawing file 205 851 164510 Rev E SP90 Transceiver Unit Outline dimensions...
Page 218: ...Simrad SP90 206 851 164510 Rev E SP90 Standard loudspeaker outline dimensions...
Page 219: ...Drawing file 207 851 164510 Rev E SP92 Hull Unit Outline dimensions...
Page 220: ...Simrad SP90 208 851 164510 Rev E SP93 Hull Unit Outline dimensions...
Page 221: ...Drawing file 209 851 164510 Rev E SP92 SP93 Mounting trunk Page 1 of 2...
Page 222: ...Simrad SP90 210 851 164510 Rev E SP92 SP93 Mounting trunk Page 2 of 2...
Page 223: ...Drawing file 211 851 164510 Rev E SP92 93 Optional trunk...
Page 224: ...Simrad SP90 212 851 164510 Rev E SP92 SP93 Blind cover for sonar trunk...
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ...E 2005 Simrad AS ISBN 10 82 8066 001 1 ISBN 13 978 82 8066 001 5...
Page 232: ......