On the main deck, the best ventilation is provided when the
outlet pipe is at least four meters higher than the inlet pipe. To
keep out sea water, rain and spray, the ventilation pipes should
be fitted with goosenecks of the equivalent.
Conduit
If the cable between the wheelhouse and the sonar room passes
through hatches or areas where it may be damaged, it should be
run through a conduit (two inch conduit is recommended).
Air vent pipe
An air vent conduit with a minimum of 10 mm internal diameter
must be attached to the air bleeding cock on the Hull Unit. The
pipe should be laid with with continuous rise to free air on deck
or through the ship’s side.
Note:
Through-hull modifications are subject to approval by the
vessel’s national registry and corresponding maritime authority.
The shipowner and shipyard are responsible for obtaining
installation approval.
Bilge pump
The sonar room should be connected to the vessel’s bilge pump
system. If this is not possible, a separate bilge pump for the
sonar room must be installed.
Lighting
The sonar room should be equipped with suitable lighting to
simplify the installation and aid future maintenance.
Dry docking
Make sure that ample space is provided between the vessel and
dry dock for system installation. To facilitate future dry docking,
mark the position of the installed trunk as indicated.
Decking
Once the installation has been completed, the sonar room should
be suitably decked without restricting access to the equipment.
References
→
Refer to page 29 for an example of a sonar room arrangement.
Related topics
→
Environmental tolerances, page 167
Summary of Contents for SP90 - REV E
Page 2: ......
Page 12: ...Simrad SP90 VIII 851 164510 Rev E...
Page 62: ...Simrad SP90 50 851 164510 Rev E Figure 10 Mounting the Transceiver Unit CD3110A...
Page 75: ...Cable layout 63 851 164510 Rev E Figure 15 SP90 Cable plan...
Page 214: ...Simrad SP90 202 851 164510 Rev E SP90 Sonar Operating Panel Outline dimensions...
Page 215: ...Drawing file 203 851 164510 Rev E SP90 Sonar Processing Unit MC70 Outline dimensions...
Page 216: ...Simrad SP90 204 851 164510 Rev E SP90 Sonar Interface Unit Outline dimensions...
Page 217: ...Drawing file 205 851 164510 Rev E SP90 Transceiver Unit Outline dimensions...
Page 218: ...Simrad SP90 206 851 164510 Rev E SP90 Standard loudspeaker outline dimensions...
Page 219: ...Drawing file 207 851 164510 Rev E SP92 Hull Unit Outline dimensions...
Page 220: ...Simrad SP90 208 851 164510 Rev E SP93 Hull Unit Outline dimensions...
Page 221: ...Drawing file 209 851 164510 Rev E SP92 SP93 Mounting trunk Page 1 of 2...
Page 222: ...Simrad SP90 210 851 164510 Rev E SP92 SP93 Mounting trunk Page 2 of 2...
Page 223: ...Drawing file 211 851 164510 Rev E SP92 93 Optional trunk...
Page 224: ...Simrad SP90 212 851 164510 Rev E SP92 SP93 Blind cover for sonar trunk...
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ...E 2005 Simrad AS ISBN 10 82 8066 001 1 ISBN 13 978 82 8066 001 5...
Page 232: ......