Start-up procedures
109
851-164510 / Rev.E
9.5 Starting up the wheelhouse units
Introduction
If the AC mains plug on the SP90 Sonar Processor Unit has
been disconnected, the initial start of the sonar must be made by
pressing the start switch
S101
. This switch is located behind the
small lid on the front panel of the Sonar Processor Unit.
The AC mains plug must be disconnected when the vessel is in
dry dock etc. This in order to prevent inadvertent use of the
sonar, which in such case could cause serious damage to the
system.
Start up
Observe the following procedure for starting up the sonar.
1
Connect the Sonar Processor Unit’s AC mains plug.
2
Press the
Power
button on the display unit.
- Check that the text
Sync...
appears on the display
.
after
approximately 10 seconds.
3
Locate the start switch
S101
behind the front door on the
front panel of the Processor Unit, and press the switch for
approximately two seconds.
4
Check that the green LED beside the
Power
button on the
Sonar Operating Panel starts blinking.
- The sonar is now loading up the sonar programme, and
after approximately two minutes, the sonar menu will
be displayed.
Figure 32
Location of switch
S101 on the SP90
Sonar Processing
Unit
Summary of Contents for SP90 - REV E
Page 2: ......
Page 12: ...Simrad SP90 VIII 851 164510 Rev E...
Page 62: ...Simrad SP90 50 851 164510 Rev E Figure 10 Mounting the Transceiver Unit CD3110A...
Page 75: ...Cable layout 63 851 164510 Rev E Figure 15 SP90 Cable plan...
Page 214: ...Simrad SP90 202 851 164510 Rev E SP90 Sonar Operating Panel Outline dimensions...
Page 215: ...Drawing file 203 851 164510 Rev E SP90 Sonar Processing Unit MC70 Outline dimensions...
Page 216: ...Simrad SP90 204 851 164510 Rev E SP90 Sonar Interface Unit Outline dimensions...
Page 217: ...Drawing file 205 851 164510 Rev E SP90 Transceiver Unit Outline dimensions...
Page 218: ...Simrad SP90 206 851 164510 Rev E SP90 Standard loudspeaker outline dimensions...
Page 219: ...Drawing file 207 851 164510 Rev E SP92 Hull Unit Outline dimensions...
Page 220: ...Simrad SP90 208 851 164510 Rev E SP93 Hull Unit Outline dimensions...
Page 221: ...Drawing file 209 851 164510 Rev E SP92 SP93 Mounting trunk Page 1 of 2...
Page 222: ...Simrad SP90 210 851 164510 Rev E SP92 SP93 Mounting trunk Page 2 of 2...
Page 223: ...Drawing file 211 851 164510 Rev E SP92 93 Optional trunk...
Page 224: ...Simrad SP90 212 851 164510 Rev E SP92 SP93 Blind cover for sonar trunk...
Page 227: ......
Page 228: ......
Page 229: ......
Page 230: ...E 2005 Simrad AS ISBN 10 82 8066 001 1 ISBN 13 978 82 8066 001 5...
Page 232: ......