381295/B
113
Procedure
1
Make sure that you have sufficient water depth
below the keel before you lower the transducer.
2
Open the
Operation
menu.
3
On the top bar, select
Hull Unit
to access the
control settings.
4
Select [
+
] and [
–
] to adjust the middle position.
5
Open the
Setup
menu.
6
On the
Setup
menu, select
Installation
.
Observe that the
Installation
dialog box opens. This dialog box contains a number
of pages selected from the menu on the left side.
a
On the left side of the
Installation
dialog box, select
System Protection
to open
the page.
b
Make sure that the upper limit of the
Tx Inhibit Hull Unit Position
does not
exceed the middle position.
c
Adjust the setting if it is necessary.
d
At the bottom of the page, select
Apply
to save your settings.
e
Close the
Installation
dialog box.
7
Lower the transducer to its middle position.
8
Start normal operation.
9
Make sure that the SN90 operates normally without transmitting into the installation
trunk.
Related topics
Defining settings related to user preferences and individual customizing, page 102