11. Maintenance / service
For maintenance and in case of service, a connection via the app is necessary to view the current status, the error history and to check and
correct the causes. A general visual inspection of the entire system, in particular for leaks, must also be carried out.
11.1. Maintenance interval:
Irrespective of desiredl intervals, it is recommended that the system be checked at least once a year by a specialist. Maintenance costs are
usually amortized, meaning that unnecessary repair costs are often avoided,m by this preventative maintenance, and therefore ongoing
costs are reduced.
11.2. Drainage, venting and shut-off possibilities
Flushing process
1
Shutting off
2
Flushing / venting
3
Flushing / draining
If flushing is required, this can be done
conveniently using the automatic flush
function.
39
Shutting off, flushing, venting
1
1
2
3
11.3. Replacing multisensors
1
Depressurise the system
2
Remove actuator
(see chapter on Installing the Secos actuator)
3
Carefully loosen the plug by opening out the catches and
pressing the plug from above. The Bus cable must not be
damaged. If necessary, press the Bus cable slightly to the
side with a plastic object to release the sensor cable.
4
Remove cap
5
Replace sensor
Fix the sensor cable so that the sensor cable does not
twist while the sensor cap is being tightened
40
Replacing multisensors
1
5
2
4
0 bar
0
3
3
3
Secos
- Simplex Energy Control System
Installation instructions
|
Operating instructions