Single Block Option Modules, Select Three (3) Maximum if No Dual Block Module is Selected;  
Select One (1) Maximum if a Dual Block Module or the Module Bracket is Selected 

Model 

Features 

Option Block Usage 

Supervisory 

Current 

Alarm 

Current 

4010-9912 

Serial DACT,  includes 2, 2080-9047 cables, 14 ft 
(4.3 m) long, RJ45 plug and spade lugs 

1 Block 

(must mount in block D 

under ESS) 

30 mA 

40 mA 

4010-9908 

4 Point Aux Relay Module 

1 Block 

15 mA 

60 mA 

4010-9916 

Voltage Regulator Module, 22.8 to 26.4 VDC 
(25 VDC nominal); isolated and resettable output; 
includes earth detection circuit and trouble relay for 
status monitoring  

1 Block 

3 A maximum 

with 2.5 A load 

4.9 A 

maximum 

with 4 A load 

4010-9918 

Dual RS-232 Module 

1 Block 

60 mA 

60 mA 

4010-9930 

Dual Class A IDNAC Isolator (DCAI); converts a 
single Class B IDNAC SLC input to two Class A or 
two Class B SLC outputs; provides short circuit 
isolation between each Class A or B output circuit; 
requires one IDNAC address; the total current 
remains controlled by the Class B input source SLC 
at 3 A maximum; select up to 2 per IDNAC SLC 

1 Block 

Note: One DCAI module can 

be mounted on the ESS 

8.3 mA 

18.5 mA 

4010-9915 

BACpac Ethernet Portal Module; requires 
4010-9918 RS-232 Module (no address required) 

1 Block 

123 mA 

123 mA 

4010-9901 

VESDA HLI 

1 Block 

60 mA 

60 mA 

Dual Vertical Block (Flat) Modules, Select One, or Two with 4010-9928 Bracket Kit 

(except for Media Cards)

 

Model 

Features 

Option Block Usage 

Supervisory 

Current 

Alarm 

Current 

4010-9928 

Dual Vertical Block Card Mounting Kit, allows 
selecting two, dual Vertical Block (flat) modules 
from the list below 

2 Vertical Blocks 

NA 

NA 

4010-9922 

Modular Network Interface Card 
(requires two media modules, see below) 

2 Vertical Blocks 

30 mA 

30 mA 

4010-9818 

Network Media Card Wired 

N/A  

(mounts to 4010-9922) 

55 mA 

55 mA 

4010-9819  Network Media Card Fiber Optic 

25 mA 

25 mA 

4010-9914 

Building Network Interface Card 

2 Vertical Blocks 

236 mA 

236 mA 

4010-9923*  SafeLINC Internet Interface 

2 Vertical Blocks 

115 mA 

115 mA 

4010-9924*  Modem Physical Bridge Class B  

Requires one of the 2 

Vertical Block spaces on the 

4010-9928 Mounting Kit 

193 mA 

193 mA 

4010-9925*  Modem Physical Bridge Class X 

246 mA 

246 mA 

4010-9926**  TCP/IP Physical Bridge Class B 

3 Block “L” Shape, requires 

one of the 2 Vertical Block 

spaces on the 4010-9928 

Mounting Kit, 

plus

 Block D  

196 mA 

196 mA 

4010-9927**  TCP/IP Physical Bridge Class X 

236 mA 

236 mA 

Dual Vertical Block (Slot) Modules, Select One if no Dual Vertical (Flat) Modules from Above are Selected

 

Model 

Features 

Option Block Usage 

Supervisory 

Current 

Alarm 

Current 

4010-9920 

8 Zone Initiating Device Circuit - Class B 

2 Vertical Blocks 

(mother/daughter card) 

75 mA 

195 mA 

4010-9921 

8 Zone Initiating Device Circuit - Class A 

*UL, ULC, and CSFM listed. 
** FM Approved only. 

Addressable Channel Loading Reference 

Device Load

Supervisory 

Current 

Alarm Current 

IDNet 2 Communications Channel Output 

for every 50 Devices

40 mA 

1 mA per device in alarm; 2 mA 
per activated device LED 

IDNAC Communications Channel Output 

for every 50 Appliances

40 mA 

calculate per selected appliances 

 

S4010-0011-5  11/2015

 Addressable Device Load Specifications for Battery Standby 

 Block Space Option Card Selection

 

 

Note:

 Refer to diagram on page 2 for Option Module availability. Supervisory and Alarm current specifications are for determining 

battery standby requirements.

 

Summary of Contents for 4010-9601

Page 1: ...either Class B or Class A operation 48 LED panel mount annunciation provides 40 Red and 8 Yellow pluggable LEDs select models meets ULC requirements optional LED kits are available to change individual LED color to Green or Blue to meet specific site requirements Optional ESS mounted modules door mounted modules and other options include City Connect with or without disconnect switches Alarm Relay...

Page 2: ...of the 4010ES ESS There are 3 available 4 x 5 blocks for mounting 4010ES hardware options Other 4010ES Options The 4010ES City Connect module or the optional Alarm Relay module mount directly to the ESS These options are mutually exclusive Network Media modules mount directly to the 4010ES Network Interface Card The TrueInsight Remote Gateway mounts on the back side of the 4010ES User Interface Pa...

Page 3: ... point category and point selection alphabet characters are not used at this time ADDITIONAL FUNCTION KEYS Event Time Request More Information Request Lamp Test Elevator Bypass City Disconnect Ground Fault Waterflow West Waterflow East Custom label insert LCD NAVIGATION CONTROL Menu selection Vertical and Horizontal position selection buttons 2 X 40 LCD READOUT LCD is backlighted during normal con...

Page 4: ...details TrueAlarm heat sensors can be selected for fixed temperature detection with or without rate of rise detection Utility temperature sensing is also available typically to provide freeze warnings or alert to HVAC system problems Readings can selected as either Fahrenheit or Celsius TrueSense Early Fire Detection Multi sensor 4098 9754 provides photoelectric and heat sensor data using a single...

Page 5: ...by appliances on the notification appliance circuit NAC making it much more difficult and costly to locate and correct the source of a problem Using the TrueAlert magnet test allows each appliance to individually identify its candela setting and address and to briefly operate if desired and using the TrueAlert ES Appliance Self Test feature provides detailed performance verification per appliance ...

Page 6: ...epending on model see model selection below for additional details on specific models Cabinet and door 6 A Enhanced System Supply details Two 3 A Class B IDNAC SLCs for up to 254 addressable notification appliances Class A operation is available using the 4010 9930 Dual Class A IDNAC Isolator DCAI module Up to 2 A of auxiliary power 110 Ah UL 50 Ah ULC battery charger 33 Ah maximum in the control ...

Page 7: ...from the list below 2 Vertical Blocks NA NA 4010 9922 Modular Network Interface Card requires two media modules see below 2 Vertical Blocks 30 mA 30 mA 4010 9818 Network Media Card Wired N A mounts to 4010 9922 55 mA 55 mA 4010 9819 Network Media Card Fiber Optic 25 mA 25 mA 4010 9914 Building Network Interface Card 2 Vertical Blocks 236 mA 236 mA 4010 9923 SafeLINC Internet Interface 2 Vertical B...

Page 8: ...representative for more details LED Kits LEDs are pluggable use to change color for local application requirements Model Description 4100 9843 8 Yellow LED Kit 4100 9844 8 Green LED Kit 4100 9845 8 Red LED Kit 4100 9855 8 Blue LED Kit End User Programming Tools Model Description 4100 8802 End User Programming Unit Software 4100 0292 Custom Label Editing USB Dongle 4100 0295 Port Vectoring Setup an...

Page 9: ...iator English 1 4606 9102CF 4010ES RUI LCD Annunciator French 1 for Canada 4602 9101 Status Command Unit SCU LED Annunciator 1 4602 9102 Remote Command Unit RCU LED Annunciator w control 1 4602 9150 Graphic I O RCU SCU Assembly for custom annunciator panels 1 4602 7101 Graphic I O RCU SCU Assembly for custom annunciator panels 1 4602 7001 RCU for cabinet mount 1 4602 6001 SCU for cabinet mount 1 4...

Page 10: ...ence Installation Instructions 579 1150 Operating Instructions 579 969 Subject Data Sheet Subject Data Sheet 4010ES Agent Release Applications and Accessories S4010 0005 Network Communications S4100 0056 Agent Release Accessories S2080 0010 Multi Signal Fiber Optics S4100 0049 Building Network Interface S4100 0061 4602 Series SCU RCU S4602 0001 SafeLINC Internet Interface S4100 0062 PC Annunciator...

Reviews: