6 Battery management
6.1 LockNodes
You can identify a communication problem (failed connection attempt) by
a red W in the LSM (see
Monitoring the devices in the network [
). If the
communication problem persists even after repeated connection
attempts, this can have a number of causes:
Radio shadow through open door
Routing problem between CommNode server and RouterNode
Communication problem between CommNode server and RouterNode,
e.g. due to blocked port 2101
(Partial) network failure, e.g. due to defective switches
Temporarily suspended IP allocation, e.g. due to maintenance work in
the network
Low batteries
You can easily check the battery condition yourself.
Signalling
The signalling of the battery status depends on the LockNode used (see
Signalling the operating status [
Warning monitor (LSM)
The LSM includes a warning monitor (| Reports |, entry Warning monitor .
You will see battery warnings for all locking devices used in the locking
system. To use this function effectively, you need a task that regularly tests
the battery status of your networked LockNodes.
WaveNet
(Manual)
6. Battery management
184 / 210