4. Click on the lower button Delete .
9
Central output router is flagged for deletion.
5. Click on the button Save .
6. Click on the Exit button.
9
Central output router is deleted. The completion of the RingCast is no
longer displayed.
Report completion of RingCast to LSM
RouterNodes cannot report the input acknowledgement (or the switching
of an output) directly to LSM. To do this, use a digital input and forward its
status to LSM (see
). This allows you to
react to the successful completion of a RingCast in the event manager.
This illustration shows the wiring when the input acknowledgement is
output on O3 or O2. Connect O3/O2 to a free digital input as shown and
forward this to the LSM. The switching behaviour is inverted by the pull-up
resistor:
Input acknowledgement active: Level at digital input 0 (Low)
Input acknowledgement not active: Level at digital input 1 (High)
DI 1
DI 2
DI 3
+3.3 V
O 3
1k
Ω
O 2
WaveNet
(Manual)
5. WaveNet Manager
135 / 210