Technical data
BA_EA-KL²-DF(-K)_EN_13
www.simon-protec.com
Date: 20.08.2019
Issue: 1.3 / 08.2019
Page 14
3.10. Mount the cover
Perform RESET-run &
test run
Mount cover
7
Figure 26
A
B
C
D
E
F
G
H
1
2
3
4
A
B
C
D
E
F
G
H
1
2
3
4
5
6
5
6
SIMON RWA
Systeme GmbH
Medienstr. 8
94036 Passau
Tel. +49 851 98870-0
Fax. +49 851 98870-70
Blatt:
Revision:
Bezeichnung:
Teile-/Artikelnummer:
Zeichnungsnummer:
Allg. Toleranz:
Oberfläche:
DIN ISO 1302
DIN ISO 2768 - m
Projekt:
Material:
gezeichnet:
Begeisterung trifft Technik
SIMON RWA
R
M.Schwinge
Drehflügel - nach innen öffnend
KL2-0.18-02-5 - Drehflügel - nach innen öffnend_3
1 / 1
04.11.2014
geprüft / geändert:
von:
am:
05.10.2017
S.Kühling
am:
von:
konstruiert:
-
Gewicht:
Maßstab:
0,06 : 1
Blattgröße:
A3
Typ:
Schutzvermerk
ISO 16016 beachten!
von:
am:
A
B
C
D
E
F
G
H
1
2
3
4
A
B
C
D
E
F
G
H
1
2
3
4
5
6
5
6
SIMON RWA
Systeme GmbH
Medienstr. 8
94036 Passau
Tel. +49 851 98870-0
Fax. +49 851 98870-70
Blatt:
Revision:
Bezeichnung:
Teile-/Artikelnummer:
Zeichnungsnummer:
Allg. Toleranz:
Oberfläche:
DIN ISO 1302
DIN ISO 2768 - m
Projekt:
Material:
gezeichnet:
Begeisterung trifft Technik
SIMON RWA
R
M.Schwinge
Drehflügel - nach innen öffnend
KL2-0.18-02-5 - Drehflügel - nach innen öffnend_3
1 / 1
04.11.2014
geprüft / geändert:
von:
am:
05.10.2017
S.Kühling
am:
von:
konstruiert:
-
Gewicht:
Maßstab:
0,06 : 1
Blattgröße:
A3
Typ:
Schutzvermerk
ISO 16016 beachten!
von:
am:
Press in all 4
tabs!
4. Technical data
Table 1: Electrical characteristics
Actuator type
EA-KL²-DF-K EA-KL²-DF
Rated voltage
24 V DC
Permissible rated voltage range
24 V DC -15 % / +15 %
Ripple of rated voltage Vpp
maximum 500 mV
Undervoltage detection
Yes
Rated current
(1)
1.1 A
1.5 A
Maximum starting current
“OPEN” / “CLOSE”
1.3 A
1.7 A
Maximum cut-off current in
“OPEN” / “CLOSE” direction
1.2 A
1.6 A
(2)
Current consumption after
cut-off (closed current)
65 mA
Cut-off via
built-in
electronic overload cut-off
Maximum permissible number
of actuator units connected in
parallel
(3)
4
Cable length between two
actuators in tandem mode
max. 10 m
Tandem stop time
(4)
3 s
Tandem-pulse time
(5)
320 ms
Protection class
III
(1)
Maximum current consumption at nominal load.
(2)
In special cases, the cut-off current in the “OPEN” direction can be increased up
to 2.0 A with SIMON LINK.
(3)
With common cut-off function (tandem function).
(4)
The stopping time (tandem) indicates how long the actuators connected in
parallel remain activated after the triggering actuator has been cut off.
(5)
The pulse time indicates how long the load cut-off via tandem sends a cut-off
signal.
ATTENTION
The rails and slides supplied and their fastening must only
be loaded with max. 500 N!
If a cut-off current > 1.6 A is selected, the rail can be over-
loaded and depending on the application, this can lead to
mechanical damage to the actuator and rail.
SIMON PROtec Systems GmbH does not assume any
warranty if the normal load on the rail is more than 500 N
due to made software settings!
Table 2: Dry contact (NO1 / NO2)
Actuator type
EA-KL²-DF-K EA-KL²-DF
Rated voltage
max. 28 V DC
Relay contact load
max. 2.0 A
ATTENTION
The maximum load capacity of the contact must not be
exceeded!