User manual - METER SRP-946
Register
Write
Range
Register description
42h
Yes
0 ÷ 999
“toFF”
parameter in
“rEL1”
menu, expressed in tenth of seconds
or tenth of minutes depend on
“unit”
parameter - register no. 43h)
43h
Yes
0 ÷ 1
“unit”
parameter in
“rEL1”
menu:
0
- seconds;
1
- minutes
44h
Yes
0 ÷ 2
“AL”
parameter in
“rEL1”
menu:
0
- no changes;
1
- on;
2
- off
45h
Yes
see descr.
“
SEt2
” parameter in “
rEL1
” menu, no decimal point included –
higher word
46h
Yes
see descr.
“
SEt2
” parameter in “
rEL1
” menu, no decimal point included –
lower word
47h
Yes
see descr.
“
SEtP
” parameter in “
rEL2
” menu, no decimal point included –
higher word
48h
Yes
see descr.
“
SEtP
” parameter in “
rEL2
” menu, no decimal point included – lower
word
49h
Yes
see descr.
“
HySt
” parameter in “
rEL2
” menu, no decimal point included –
higher word
4Ah
Yes
see descr.
“
HySt
” parameter in “
rEL2
” menu, no decimal point included –
lower word
4Bh
Yes
0 ÷ 5
“
modE
” parameter in “
rEL2
” menu:
0
- “
noAC
” mode;
1
- “
on
” mode;
2
- “
oFF
” mode;
3
- “
in
” mode;
4
- “
out
” mode;
5
- “
modb
” mode
4Ch
Yes
0 ÷ 999
“t on”
parameter in
“rEL2”
menu, expressed in tenth of seconds or
tenth of minutes depend on
“unit”
parameter - register no. 4Eh)
4Dh
Yes
0 ÷ 999
“toFF”
parameter in
“rEL2”
menu, expressed in tenth of seconds
or tenth of minutes depend on
“unit”
parameter - register no. 4Eh)
4Eh
Yes
0 ÷ 1
“unit”
parameter in
“rEL2”
menu:
0
- seconds;
1
- minutes
4Fh
Yes
0 ÷ 2
“AL”
parameter in
“rEL2”
menu:
0
- no changes;
1
- on;
2
- off
50h
Yes
see descr.
“
SEt2
” parameter in “
rEL2
” menu, no decimal point included –
higher word
51h
Yes
see descr.
“
SEt2
” parameter in “
rEL2
” menu, no decimal point included –
lower word
52h
Yes
see descr.
“
SEtP
” parameter in “
rEL3
” menu, no decimal point included –
higher word
53h
Yes
see descr.
“
SEtP
” parameter in “
rEL3
” menu, no decimal point included – lower
word
54h
Yes
see descr.
“
HySt
” parameter in “
rEL3
” menu, no decimal point included –
higher word
55h
Yes
see descr.
“
HySt
” parameter in “
rEL3
” menu, no decimal point included –
lower word
56h
Yes
0 ÷ 5
“
modE
” parameter in “
rEL3
” menu:
0
- “
noAC
” mode;
1
- “
on
” mode;
2
- “
oFF
” mode;
3
- “
in
” mode;
4
- “
out
” mode;
5
- “
modb
” mode
53