background image

Troubleshooting 

9

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Symptom

Possible Cause(s)

Corrective Action

Motor will not run

Disconnect switch is off

Be sure switch is on.

Fuse is blown or circuit breaker tripped

Replace fuse or reset circuit breaker.

Starting switch is defective

DISCONNECT POWER; Replace starting switch.

Wires at motor are loose, disconnected, or 
wired incorrectly 

Refer to instructions on wiring (Page 9). DISCONNECT POWER; check and 
tighten all wiring.

 Capacitor voltage may be hazardous. To discharge capacitor, 

hold insulated handle screwdriver BY THE HANDLE and short capacitor 
terminals together. Do not touch metal screwdriver blade or capacitor terminals. 
If in doubt, consult a qualified electrician.

Pressure switch contacts are dirty

DISCONNECT POWER and file contacts with emery board or nail file.

Motor runs hot and overload 
kicks off

Motor is wired incorrectly

Refer to instructions on wiring.

Voltage is too low

Check with power company. Install heavier wiring if wire size is too small (See 
Electrical / Wiring Chart).

Pump cycles too frequently

See section below on too frequent cycling.

Motor runs but no water is 
delivered*

Pump in new installation did not pick up 
prime through:
1. Improper priming
2. Air leaks
3. Leaking foot valve or check valve

In new installation:
1. Re-prime according to instructions.
2. Check all connections on suction line, AVC, and ejector with soapy water or 
shaving cream.
3. Replace foot valve or check valve.

Pump has lost prime through:
1. Air leaks
2. Water level below suction pipe inlet

In installation already in use:
1. Check all connections on suction line and shaft seal.
2. Lower suction line into water and re-prime. If receding water level in well 
exceeds 25’ (7.6M), a deep well pump is needed.

Foot valve or strainer is plugged

Clean foot valve or strainer.

Ejector or impeller is plugged

Clean ejector or impeller.

Check valve or foot valve is stuck shut 

Replace check valve or foot valve.

Pipes are frozen

Thaw pipes. Bury pipes below frost line. Heat pit or pump house.

Foot valve and/or strainer are buried in 
sand or mud

Raise foot valve and/or strainer above bottom of water source. Clean foot valve 
and strainer.

Water level is too low for shallow well 
setup to deliver water

A deep well jet will be needed if your well is more than 25’ (7.6M) depth to 
water.

Pump does not deliver water to 
full capacity (Also check point 
3 immediately above)

Water level in well is lower than estimated

A new nozzle and venturi combination may be needed.

Steel piping (if used) is corroded or limed, 
causing excess friction

Replace with plastic pipe where possible, otherwise with new steel pipe.

Piping is too small in size

Use larger piping.

Pump delivers water but does 
not shut off or pump cycles too 
frequently

Pressure switch is out of adjustment or 
contacts are welded together

DISCONNECT POWER; adjust or replace pressure switch.

Faucets have been left open

Close faucets.

Venturi, nozzle or impeller is clogged

Clean venturi, nozzle or impeller.

Standard pressure tank is waterlogged and 
has no air cushion

Drain tank to air volume control port. Check AVC for defects. Check all 
connections for air leaks.

Pipes leak

Check connections.

Foot valve leaks

Replace foot valve.

Pressure switch is out of adjustment

Adjust or replace pressure switch.

Air charge too low in pre-charged tank

DISCONNECT POWER and open faucets until all pressure is relieved. Using 
tire pressure gauge, check air pressure in tank at valve stem located on the tank. 
If less than pressure switch cut-in setting (30-50 PSI), pump air into tank from 
outside source until air pressure is 2 PSI less than cut-in setting of switch. Check 
air valve for leaks (use soapy solution) and replace core if necessary.

Air spurts from faucets

Pump is picking up prime

When pump has picked up prime, it should pump solid water with no air.

Leak in suction side of pump

Suction pipe is sucking air. Check joints for leaks with soapy water.

Well is gaseous

Consult factory about installing a sleeve in the well.

Intermittent over-pumping of well. (Water 
drawn down below foot valve.)

Lower foot valve if possible, otherwise restrict pump discharge.

* Stop pump; then check 

prime before looking for 

other causes. Unscrew 

priming plug and see if 

water is in priming hole.

Summary of Contents for 2806E

Page 1: ...ents concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages 12 21 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o ma...

Page 2: ...tor terminals If in doubt consult a qualified electrician General Safety Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump a...

Page 3: ...cations Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination...

Page 4: ...0 to 600 Ft Tank Tank is pre charged with 40 pounds per square inch PSI air pressure at the factory Your tank requires an air charge of 28 PSI for proper operation check tank pressure with tire gauge...

Page 5: ...onnections Cased Well Installation 2 or Larger Casing Figure 2 1 Mount the pump as close to the well as possible 2 Assemble the foot valve strainer and well pipe see Figure 2 Make sure that the foot v...

Page 6: ...p Sealing Pipe Joints Use only PTFE pipe thread sealant tape or PTFE based joint compounds for making all threaded connections to the pump itself Do not use pipe joint compounds on plastic pumps they...

Page 7: ...plicable and with all local codes and ordinances that apply Consult your local building inspector for code information Connection Procedure 1 Connect the ground wire first as shown in Figure 4 The gro...

Page 8: ...ime 4 After the pump has built up pressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump s...

Page 9: ...r pump house Foot valve and or strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well se...

Page 10: ...n Part Number 1 Motor J218 582A 115 PKG 2 Seal Plate Assembly N3 9 3 Seal and Gasket Kit FPP1550 P2 4 Pump Body Assembly N176 38 5 Overhaul Kit FPP1560 P2 6 Pressure Switch U217 1202 Includes Water sl...

Page 11: ...alve and Cap 1 U212 160 3 Replacement Tank 1 HT7 01 4 Inlet Flange 1 U31 442P 5 Nut 5 16 18 Hex 6 U36 202BT 6 Elbow 3 4 MPT x 1 Insert 1 U78 770P 7 Clamp 2 U19 55SS 8 Hose 1 x 29 1 2 1 U74 37L 9 Disch...

Page 12: ...us pour fonctionner par des temp ratures lev es Pour ne pas se br ler lorsque l on interviendra sur la pompe la laisser refroidir pendant 20 minutes apr s l avoir arr t e avant de la toucher Ne pas l...

Page 13: ...t qui a t install e au d taillant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillan...

Page 14: ...r est pr charg avec une pression d air de 40lb po2 l usine Le r servoir requiert une charge d air de 28 lb po2 pour fonctionner correctement V rifier la pression du r servoir l aide d un manom tre pou...

Page 15: ...ent In stallation sur un puits tubage de 2 pouces de diam tre ou plus grand Figure 2 1 Monter la pompe aussi pr s que possible du puits 2 Brancher le clapet de pied la cr pine et le tuyau du puits voi...

Page 16: ...icit pour les branchements lectriques tanch it des raccords des tuyaux N utiliser que du ruban d tanch it en PTFE pour filetage base de PTFE pour proc der tous les raccords filet s sur la pompe Ne pas...

Page 17: ...eur de la municipalit Consulter l inspecteur des b timents de la localit pour plus de renseignements sur les codes M thodes de connexion 1 Brancher tout d abord le fil de mise la terre comme il est il...

Page 18: ...e et que la pompe se sera arr t e v rifier le fonctionnement du manocontacteur en ouvrant un ou deux robinets du syst me laisser couler suffisamment d eau pour dissiper la pression jusqu ce que la pom...

Page 19: ...pet de pied et ou la tr mie sont enfouis dans le sable ou la boue Relever le clapet de pied et ou la cr pine plus haut que le fond de la source d eau Nettoyer le clapet de pied et la cr pine Dans le c...

Page 20: ...2 Plaque d tanch it N3 9 3 Trousse de joints d tanch it FPP1550 P2 4 Corps de la pompe N176 38 5 Trousse de r paration FPP1560 P2 6 Pressostat U217 1202 Comprend D flecteur d eau joint de la plaque d...

Page 21: ...bouchon 1 U212 160 3 R servoir de rechange 1 HT7 01 4 Bride d admission 1 U31 442P 5 crou six pans de 5 16 18 6 U36 202BT 6 Coude de 3 4 de po MPT x garniture de 1 po 1 U78 770P 7 Collier 2 U19 55SS...

Page 22: ...para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del sistem...

Page 23: ...o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacales que hayan...

Page 24: ...SI para un funcionamiento correcto verifique la presi n del tanque con un man metro para neum ticos y ajuste la carga de aire seg n sea necesario Es importante chequear la precarga del tanque anualmen...

Page 25: ...l tanque de presi n Instalacion de pozo recubierto con un recubrimiento de 2 o mas Figura 2 1 Monte la bomba tan cerca del pozo como sea posible 2 Instale la v lvula de retenci n el filtro y la tuber...

Page 26: ...de Juntas de Tuber a Utilice solamente sellante de PTFE para roscas de tuber a a base de PTFE para todas las conexiones de rosca a la bomba No use compuestos de burlete para tuber as en bombas de pl...

Page 27: ...local de construcciones para obtener informaci n sobre los c digos Procedimiento para las conexiones 1 Conecte el alambre de puesta a tierra primero seg n se ilustra en la Figura 4 El alambre de pues...

Page 28: ...ve o dos y dejando correr suficiente agua para descargar la presi n hasta que la bomba arranque La bomba debe arrancar cuando la presi n caiga a 30 PSI y se debe detener cuando la presi n alcance los...

Page 29: ...iente el recinto de bombas o el foso La v lvula de pie y o el colector est n enterrados en arena o en lodo Eleve la v lvula de pie y o el colector por encima del fondo de la fuente de agua Limpie la v...

Page 30: ...stanqueidad N3 9 3 Juego de junta y empaquetadura FPP1550 P2 4 Unidad del cuerpo de la bomba N176 38 5 Juego de acondicionamiento FPP1560 P2 6 Man stato U217 1202 Incluye Deflector de agua empaquetadu...

Page 31: ...casquete 1 U212 160 3 Tanque de repuesto 1 HT7 01 4 Brida de admisi n 1 U31 442P 5 Tuerca hexagonal de 5 16 18 6 U36 202BT 6 Codo de inserci n de 3 4 MPT x 1 1 U78 770P 7 Abrazadera 2 U19 55SS 8 Mangu...

Page 32: ......