D) Block the inlet port if the boiler has already been used with wood or coal.
E) Insert the micro pressing pin into the hole on the combustion chamber door and adjust its projection with nut M6.
F) Insert the hard-wired safety microswitch into the hole on the left side of the mantle. Adjust the projection using the hex jam nuts. Check the
operation after assembly.
G) Assemble the two-stage burner fixing it onto the flange by means of the previously disassembled nuts in order to remove the blind flange in
cast iron. Assemble the flame baffle.
Fig. 13.6: Inlet port
Fig. 13.11: Assembly of burner
Fig. 13.12: Assembly of flame baffle
Fig. 13.7: Assembly of micro pressing pin
Fig. 13.8: Pin closing position
27/28 mm
Fig. 13.9: Assembly of microswitch
Fig. 13.10: Microswitch position
7 mm