76
2.2 INSTALLATION
2.2.1
CONFIGURATION OF THE BOILER FOR THE USE WITH PELLETS AND OPTIONAL KIT
A) Remove the blind flange in cast iron and disassemble the grille, hinge and hake along with the setting screws.
B) Assemble the five baffles supplied, pushing the first deflector against the rear head of the boiler and then the others.
C) Disassemble the boiler thermostatic valve, if present, and close the hole with the cap supplied. Disassemble also the boiler thermometer, if
fitted, and close the hole on the front piece with the plastic cap supplied.
Fig. 13: Disassembly of blind flange
Fig. 13.1: Disassembly of grille
Fig. 13.2: Assembly of baffle
Fig. 13.3: Assembly of baffle
Fig. 13.4: Assembly of cap
Fig. 13.5: Closing the front piece