46
SAFETY STAT (fig. 9)
RX TP models. are. equipped. with.
safety. stat. (3). with. manual. reset-
ting..In.case.the.boiler.temperature.
exceeds. 95°C. the. safety. stat. will.
extinguish. the. pilot. burner. thus.
shutting.off.the.gas.flow.to.the.pilot.
and.main.burner.
Should. the. stat. trip. off,. it. will. be.
necessary.to.unscrew.the.cover.and.
reset. the. button. below. for. the. pilot.
burner.to.restart.
ATTENTION: Should the boiler
“lock out” again, you must call the
authorized technical staff.
SMOKE SAFETY DEVICE (fig. 10)
It. is. a. safety. device. which. controls.
the.correct.discharge.of.flue.gas.into.
the.atmophere.(3)..
The. control. device. stops. the. gas.
valve. if. the. flue. gas. is. descharged.
into. the. boiler. room. is. continuous.
way. and. in. such. quantities. as. to.
become.dangerous..
To.start.the.boiler.again,.switch.off.
the.power,.then.remove.the.smoke.
stat. cover. and. reset. the. button.
below...
ATTENTION: If the boiler stops
again, it will be necessary to call
the authorized technical staff.
GAS CONVERSION
Should. a. gas. other. than. that. for.
which.the.boiler.is.equipped.be.used,.
the.conversion.has.to.be.carried.out.
by.technical.personel.authorized.by.
the.manufacturer.
CLEANING AND MAINTENANCE
When.the.heating.is.turned.off.at.the.
end. of. the. season,. it. is. compulsory.
to.check.the.boiler.and.clean.it.
Maintenance
and
check
of
equipment and safety devices shall
be carried out only by authorized
technical personel.
DISPOSAL OF THE
EQUIPMENT
Once. it. reaches. the. end. of. its. ope-
rating.life,.the.equipment.MUST.BE.
RECYCLED.in.line.with.current.legi-
slation.
IT. MUST. NOT. be. disposed. of. toge-
ther.with.urban.waste.
It. can. be. handed. over. to. recycling.
centres,.if.there.are.any,.or.to.retai-
lers.that.offer.this.service.
Recycling. prevents. potential. dama-
ge. to. the. environment. and. health..
It. allows. to. recover. a. number. of.
recyclable. materials,. with. conside-
rable.savings.in.terms.of.money.and.
energy.
2
1
4
3
Fig..10
KEY
. 1. Boiler.stat
. 2. Thermometer
. 3. Smoke.stat
. 4. Hydrometer
Summary of Contents for RX 19 TP
Page 1: ...Fran ais English Cod 6091836 02 2017...
Page 2: ...1 2 3 4...
Page 3: ...1 1 1 RX TP G30 G31 1 2 1 2 1 RX TP 19 26 1 R M G...
Page 4: ...1 2 2 RX TP 37 48 55 1 a 1 R 1 M 3 4 G...
Page 6: ...1 4 2 1 2 3 4 5 6 7 8 9 LED 10...
Page 8: ...G20 2 0 G30 G31 2 2 1 2 3 A 500 20...
Page 9: ...2 3 1 4 UNI 7129 92 35 2 4 RX TP 5 7 mVcc 250 300 mVcc...
Page 10: ...2 4 1 5 TR TF TS TP T VP BP TA 1 2 5...
Page 11: ...3 1 M12 2 3 4 M12 5...
Page 12: ...3 1 6 8 2 RX TP 37 55 12 5 M12 3 2 SIT 820 SIT 820...
Page 13: ...4 4 1 820 7 1 2 3 4 7 8 9 7 20 37 1 20 8 2 1 3...
Page 14: ...4 3 6 1 3 4 4 8 1 2 3 4 5...
Page 15: ...4 4 8 G30 G31 2 7 30 37 4 5 4 6 4 6 1 RX TP 19 26 RX TP RX TP 37 55...
Page 16: ...4 6 2 4 6 3 4 6 4 700 800 300mV 4 6 5 5 7 4 6 6 4 7...
Page 17: ...3 1...
Page 18: ...1 9 1 2 3 A B C OFF...
Page 19: ...A 2 B 10 1 2 3 4 1 45 85 2 60 OFF 9 OFF C...
Page 20: ...9 3 95 10 3 GAZ...