67
7 MAINTENANCE
7.1
Servicing
As a condition of the warranty and to ensure correct operation
and efficiency, it is important that the boiler is serviced every
12 months, within 30 days of the anniversary of the installa-
tion date ensure the required information is recorded in the Gas
Boiler System Service Interval Record (page 75) (Benchmark).
m
CAUTION
– Only qualified persons in compliance with the in-
structions contained in this manual are permitted
to install, commission and maintain this boiler.
Suitable protective safety equipment
MUST be worn
.
The installation of this boiler must be in accordance
with the relevant requirements of the current Gas
Safety (installation and use), the local building reg-
ulations, and I.E.E. wiring regulations.
– Make sure that the system components and pipes
are not hot (risk of burning).
a
WARNING
Before carrying out any interventions described:
– isolate the power supply
– isolate the gas cock
– avoid contact with any hot surfaces.
OFF
Fig. 160
7.2
External cleaning
7.2.1
Cleaning the case
When cleaning the cladding, use a cloth dampened with soap
and water or alcohol for stubborn marks.
d
DO NOT
Do not use abrasive products.
7.3
Burner Inspection
7.3.1
Burner access
To access the internal parts of the boiler:
– open the two catches (1), unscrew the two screws (2), pull
the front panel (3) forwards and release it from the top by
lifting it.
3
2
1
2
Fig. 161
– remove the screws (4) securing the control panel (5)
– move the panel (5) upwards (a) but keeping it in the side
guides (6) to the end of travel
– bring it forwards and down (b) until it is horizontal
a
b
6
5
4
Fig. 162