37
Once the packaging has been removed, the appliance can be
handled manually, lifting it by gripping the points indicated in
the figure.
NO!
Fig. 51
d
DO NOT
To grip the appliance casing. Hold the "solid" parts of
the appliance such as the base and structural frame.
a
WARNING
When moving the appliance and removing the pack-
aging,
the user must
:
–
respect the maximum weight restrictions for lifting
per person
– use suitable tools and safety devices.
5.4
Ventilation requirements
The room where the appliance is to be installed must comply
with the technical regulations and legislation in force. No aer-
ation vents are required because the approved installation is
ONLY “TYPE C”
.
The minimum temperature of the installation room must NOT
be lower than
-5 °C
.
APPROXIMATE MINIMUM DISTANCES
≥ 50 mm
≥ 500 mm
A
A
The necessary height for plumbing and gas
connections is decided during installation.
Fig. 52
5.5
New installation or installation of a re-
placement appliance
The boiler must be installed in a fixed location and only by spe-
cialized and qualified person in compliance with all instructions
contained in this manual.
The installation of this boiler must be in accordance with the
relevant requirements of the current Gas Safety (installation
and use), the local building regulations and I.E.E. wiring reg-
ulations.
Detailed recommendations for air supply and fluing are given
in BS5440.
The following notes are for general guidance: it is not neces-
sary to have a purpose provided air vent in the room or com-
partment in which the appliance is installed.
m
CAUTION
It is a condition of the warranty that the boiler is in-
stalled in accordance with the instructions in this
manual. The boiler must be registered with Gas Safe
Register, the Benchmark record must be completed
and the boiler is serviced annually and recorded in
this manual.
m
CAUTION
If the domestic water supply is metered or should a
water meter be added at a later time, a small expan-
sion vessel should be included in the domestic water
pipework.