57
The full list of configuration parameters can be found in the ta-
bles below.
Room sensor parameters
Parameter Description
Type
OFF
= No zone room sensor present
OT
= Zone controlled directly via remote control (OT)
TA
= Zone managed directly by room thermostat (TA)
connected in the boiler
RF
= Zone managed directly by wireless sensor (RF)
M3
= Zone manage by wired sensor on M3 bus
M3 ad-
dress
[ 0 … 3 (Default = 0) ]
= Address for device connected to
bus M3, holding the input sensor, whether M3 or RF
installed on an RF concentrator. This address is usually
set via the dipswitch on the device itself
Input
[ 1 … 8 (Default = 1) ]
= Input number for the RF concen-
trator (sometimes virtual, as for RF) to which a sensor or
generic input will be associated
Status
--
= Status awaiting verification
OK
= Installation complete / sensor present
…
= Being installed (waiting for RF sensor on selected RF
concentrator)
ERR
= Installation or configuration error
Water circuit parameters (hydraulic)
Parameter Description
Type
OFF
= Zone and circuit not present or not controlled
CALD
= Circuits integrated in the boiler (fixed: Circuit 1
for Zone 1 and Circuit 2 for Zone 2)
ATT
= Circuits managed by actuator on bus M3
M3 ad-
dress
[ 0 … 3 (Default = 0) ]
= Address for device connected to
bus M3, actuator M3, holding the output relay, whether
single or multiple (Mix), on an actuator. This address is
usually set via the dipswitch on the device itself
Output
[ 1 … 4 (Default = 1) ]
= This is the physical output number
(e.g. single or multiple relay) of the actuator M3 to which
the hydraulic circuit for the selected zone will be asso-
ciated. For Mix zones, select 1 (even though the relays
used are 1, 2 and 3)
Category
DIR
= Direct circuit (high temperature)
MIX
= Mixed circuit (low temperature)
Status
--
= Status awaiting verification
OK
= Installation complete / sensor present
…
= Being installed (waiting for RF sensor on selected RF
concentrator)
ERR
= Installation or configuration error
m
CAUTION
The settings described above must be done for all
zones.