29
Fig. 15
3.9
“MURELLE GREEN PLANET 110 HE I - E” WITH COMPENSATOR KIT CODE 8101581 AND TANK “BT” SERIES OPTIONAL (fig. 15)
600
1000
4500
4000
3500
3000
2500
2000
1500
PORTATA (l/h)
PERDITE DI C
ARICO TRA
GLI A
TT
A
CC
HI R3 e M2 (mbar)
500
400
100
200
300
700
800
5000 5500
Murelle HE 110 R
LOAD LOSS SLOPE/FLOW BETWEEN R3 and M2 CONNECTIONS
The D.H.W. cylinder pump to be used must
be sized in according to the losses of the
domestic circuit (cylinder and pipework)
and to ensure the minimum flow (3.800
l/h).
FLOW (l/h)
LOAD LOSS
BETWEEN
R3 e M2 CONEXIONES (mbar)
Murelle Green Planet 110 HE I - E
KEY
1 Gas
valve
2 Condensation drain trap
3 Heating return sensor (SR)
4
Fan
5
Heating Flow Sensor
(SM)
6 Safety
thermostat 95°C
7 Exhaust sensor (SF)
8
Primary heat exchanger
11 Water pressure transducer
12
Auto Air Vent
13 Pump
14
Manual drain vent
15
Gas cock
(supplied with kit 8101531)
16
Non return valve
17
5 BAR safety valve
18
Non return valve
(not provided)
19 Hydraulic compensator
(provided in the kit)
20
Drain tap
(provided in kit)
21
8-liter expansion vessel
(provided in the kit)
22
Air relief valve
(provided in kit)
23
Oblique filter
(not provided)
29 DHW cylinder (not provided)
31
Cylinder pump (not provided)
CONNECTIONS
M
Heating flow
R
Heating return
G Gas
S3
Condensation drain
M2
Tank flow
R3
Cylinder return
18
31
29
M2
R3
8
12
3
11
13
14
16
17
1
2
15
21
22
19
20
M
R
G
S3
4
6
5
7
23