70
2.5.6 CLEANING (fig. 60)
Cleaning operations must be carried out
at regular intervals and only when the
boiler is cold.
Combustion residuals collect in the
removable drawer that must be emptied
before starting the boiler.
ATTENTION: To release and open the
bottom door, lift the locking bracket (A).
To remove all combustion residuals, use
an ordinary aspirator and verify that all
the ashes inside the combustion cham-
ber have been completely removed. The
aspirator can also be used to clean the
pellet grille.
To clean the fume ducts inside the boiler
body, use a wiper.
ATTENTION: if the generator is switched
off for long periods of time (above 15
days), it is necessary to empty the 80
kg pellet container in order to prevent
the pellets from absorbing excessive
humidity, which could affect the opera-
tion of the boiler.
A high amount of humidity in the pellets
could cause them to pulverize, increase
the amount of residuals in the brazier
and obstruct the pellet feeding system.
2.5.7
SAFETY THERMOSTAT (fig. 61)
The safety thermostat with manual reset
intervenes automatically, switching off
the burner, when the water heater tem-
perature exceeds 95°C.
To start the water heater back up again,
press the button as shown in the figure.
During the resetting procedure one must
not remove the bracket that protects the
thermostat.
If this event occurs frequently, have
qualified staff inspect the equipment.
2.5.8
ANNUAL MAINTENANCE
For optimum performance, it is advis-
able to have the boiler inspected accu-
rately and thoroughly by qualified per-
sonnel at least once every season.
Before performing maintenance opera-
tions, verify that the boiler is cold and
has been disconnected from the mains.
2.5.9
APPLIANCE DEMOLITION
AND DISPOSAL
When the appliance reaches the end of
its service life, it MUST BE DISPOSED of
SEPARATELY, as set forth by the laws
in force.
IT MUST NOT be disposed of as urban
waste.
It may be taken to the separate waste
collection centres, if any, or to a dealer
providing this service.
Separate disposal prevents potential
damage to the environment and health.
It also allows many recyclable materials
to be retrieved with significant economic
and energy savings.
2.5.10
ACCESSORIES
- 5197500
200-litre PELLET TANK
- 5197510
300-litre PELLET TANK
- 5197520
500-litre PELLET TANK
Fig. 60
Removable
drawer
Pellet grille
Fig. 61
A
Summary of Contents for 8058540
Page 71: ......