![Sime 8058540 Manual Download Page 64](http://html.mh-extra.com/html/sime/8058540/8058540_manual_1274876064.webp)
64
FUEL FEEDER FILLING FUNCTION
The “Fuel feeder filling” option (“Charge Pellet” shown on the display) is displayed in the menu only if the heater is OFF, and it is aimed
to let the auger feeder being filled with pellet.
When the key Set (key #3) is pressed, the panel changes screen (See “Fig. 53 Pellet feeder filling function”). By pressing esc (key #1) the
display reverts back to the previous screen, while the key Ok (key #3) starts the function, showing the confirmation (See “Fig. 54 Pellet
feeder starting up”). By pressing the button esc (key #1) the previous screen is restored and the function is stopped. When the function
is active, it may be stopped by pressing the button On/Off (key #5), while the display reverts back to the START screen.
e s c
O k
C h a r g e
P e l l e t
Fig. 53
Pellet feeder filling function
e s c
A b i l i t a t i o n
C h a r g e
P e l l e t
Fig. 54
Pellet feeder starting up
BURNER POT CLEANING
The “Burner pot cleaning” option (“Cleaning” shown on the display) is displayed in the menu only if the heater is OFF (See “Table 12
Maintenance menu functions list”), and it is aimed to let the fuel feeder being filled with pellet.
When the key Set (key #3) is pressed, the panel shows a screen similar to that used for filling the auger feeder with pellet (See “Fig. 53
Pellet feeder filling function”). By pressing esc (key #1) the display reverts back to the previous screen, while the key Ok (key #3) starts
the function, showing the confirmation. Stopping the burner cleaning function is gotten in the same way as for the “pellet filling” function
(by pressing again the key #3).
PUMP ACTIVATION
The option”pump activation” option (“Start pump” shown) is displayed in the menu only if the heater is in OFF status and the “HYDRO”
mode is on (See “Table 12 Maintenance menu functions list”). It is aimed to drive on the heating circuit pump in order to have the heating
pipework filled with water more quickly while letting air bubbles flowing out easier by the purge valves. This function works in the same
way as the previous two ones.
2.5.4.5 TECHNICAL MENU
This menu is intended for service purposes, and includes the setting of all the items reserved for technical personnel only; accessing this
menu is password protected (See Fig. 55).
e s c
W
0 6
O k
<
P a s s w o r d
>
Fig. 55
PASSWORD screen
The password is split into a letter and a numeric part, which may be changed. The two bottom keys with arrows allows the user to toggle
the currently blinking item; the letter part of the password will be confirmed firstly by pressing the key Ok (key #3); after that the numeric
part may be confirmed. If both parts are not set correctly the sequence starts again from the beginning.
Summary of Contents for 8058540
Page 71: ......