66
Test Menu
Startup Bypass
Test Reset
Pellet Feeder
Extractor (exhauster fan)
Fan 1
Fan 2
Pump
Igniter
Photoresist. Calibration On
Photoresist. Calibration Off
Table 12
Maintenance menu functions list
*
This value may be set to 2 only if the 2nd exhauster fan is disabled.
**
The maximum value which can be displayed depends on the set value, controlled by the board.
*** This function is hidden with the 2nd exhauster fan disabled.
To access the selected menu, press key Set (key #3); from within the submenu, the item value may be changed by pressing the key Set
(key #3): The value shown on the top line starts blinking to let the user being informed that it may be now changed, while “Set” is replaced
by “Ok”; the two bottom keys may be two arrows or may also change in +/-, depending on the displayed data type, and they are used to
increase or decrease the item value. By pressing the button Ok (key #3) the new value is confirmed and the display reverts to the previ-
ous screen (unflashing).
The display will return to the previous screen without confirming the new value by pressing the esc key (key #3). Each submenu item
and its value stay displayed for 60s; after that time the display reverts back to the START screen. By pressing the On/Off key (key #5) the
display will return to the START screen without confirming the new value.
The running time reset function deserves a more detailed explanation due to its behaviour and screen, different from those of the other
functions.
When the key Set (key #3) is pressed, the running time starts blinking; the value shown may be reset by pressing key Ok (key #3) (See
Fig. 56)
e s c
2 0 0 0
O k
R e s e t
S e r v i c e
T
Fig. 56
Running time reset
Summary of Contents for 8058540
Page 71: ......