IQ Power HL Power Supply
5201258 Rev. C
5. OPERATION
NOTE
– Before switching on power; ensure that units are properly grounded
and that static bars and sensors are properly installed.
Power Supply Indicators
Power:
Lights (green) to indicate power is on and the IQ Power HL Power Supply
is ready to operate.
Bar On
: Lights (green) to indicate when static neutralizing bar is active.
Fault
: Lights (red) to indicate faulty condition of static bar, power supply or
high voltage connections. Power will have to be turned off to clear the fault.
When the fault is cleared and power is restored, the fault light will be extinguished.
Clean Bar
: Lights (yellow) to indicate need to clean static bar. Clean Bar
indicator may light with low ion output (dirt build-up on ion emitters) or high
output current (conductive contamination on face of bar).
Output
: The (green) indicators are “Low”, “Medium” and “High” and light to
indicate the system relative ion output. The output will normally be in the high
and medium range. Low output generally indicates the need to clean the static bar.
Bar Type
: The indicator next to the type of bar connected will light (green).
“Speed” or “Hybrid” will be indicated. In cases where two different types of
bars are connected, the system will set for the safer of the two operating voltages
and light the corresponding Mode indicator.
Calibrate Locked
: The (green) indicator lights when the power supply is connected
to a Control Station and the Calibrate button on the HL power supply is locked out.
In this case, calibration must be performed through the Control Station.
Power Supply Operators
Calibrate
: Is a momentary push button switch located on the face label. Pressing
the face label firmly on “Calibrate” initiates calibration sequence and sets relative
nominal ion output for the system.