![Simco-Ion IQ Power HL Installation And Operating Instructions Manual Download Page 14](http://html1.mh-extra.com/html/simco-ion/iq-power-hl/iq-power-hl_installation-and-operating-instructions-manual_1274778014.webp)
12
IQ Power HL Power Supply
5201258 Rev. C
G.
Connect Control Station
(if used). The Control Station supplies 24 VDC power
for the IQ Power static eliminator power supplies. Use the 2.13 meter [7 foot]
(black) modular cable supplied with unit. Longer cables (not supplied) are
available. Cables must be IQ Power 8-conductor modular cables with RJ-48
connectors wired “crossover” (reference color: black, Figure 5).
The modular cable plugs into one of the connectors labeled “POWER &
COMM” on the Control Station and into either “PS COMM 1” connector on
the HL power supply, see Figure 7.
The modular cable should not be run parallel with static bar high voltage
cable. Route modular cable clear of moving machine parts and protect it from
abrasion. Secure using nylon wire ties (not supplied). Do not over-tighten wire
tie.
If there is an excess of modular cable, do not coil it in vicinity of static bar high
voltage cable. If possible, cut modular cable to length and re-terminate using
an RJ-45 connector installed with the same “polarization” as connector removed
(note rib / wire color code to modular connector).
If multiple IQ Power supplies are connected to the Control Station, each power
supply must have a unique Power Supply Number (address / device number).
This is necessary to enable reliable digital communication.
The Control Station can be used to automatically address the power supplies.
The default Power Supply Number for a new unit is “1”. Plug the first power
supply (only) into the Control Station and turn Control Station on. Allow
Control Station to boot-up and begin operation. Plug second power supply
into Control Station. The Control Station will re-address the second power
supply to “2”. Plug third power supply into Control Station. The Control
Station will re-address the third power supply to “3”. Repeat this process until
all power supplies (or IQ Power / IQ Easy devices) are installed. Each power
supply or device will be given a unique address (device number).
IQ Power HL power supplies may also be manually re-addressed through the
control station.