24
ht5000HB - pro5dl
Any variation takes place only after pressing the confirmation
key (+). The confirmation may take effect:
immediately
•
, for transition for 'Double' to 'Single' mode
or vice versa
delayed
•
(at next start-up from standby), for transition in the
ambit of Single mode.
iN ThE gRAPhiC REPRESENTATiON:
a selected lamp is shown by having the corresponding
•
number underlined
a lamp that is in operation is shown with a symbol above
•
the corresponding number
a lamp being turned on or cooling off is shown by symbols
•
alongside the corresponding number.
If a lamp fails to light, the projector will attempt to provide
projection in the best conditions possible:
if in "Double" mode, by turning on the lamp that is still
•
working
if in "Single" mode, by turning on the other lamp, i.e. the
•
one that is not selected.
MENU
LANgUAgE
Makes it possible to select one of the languages available for
the On Screen Display menus.
SOURCE LiST
In order to make the HT5000HB - PRO5DL system increas-
ingly flexible, the functions described below make it possible
to modify the input selection menu and adapt it so that it
matches the requirements of the user more closely. The main
page displays all the source inputs physically connected to
the projector.
You can delete any inputs which are not in use. To do this,
select the input in the pull down menu which appears when
you press
◀
, and choose whether to enable or disable the
input (Fig. 32).
Enabling or disabling of sources will automatically cause the
renumbering of the remaining active inputs.
Lamp Power
Lamp Manangement
Test Pattern
Initial Settings
300
1 2
Lamp Mode
Single
Double
Cancel
Confirm
Lamp Selection
2
1
Alt
+
-
Lamp Management
Fig.31
Menu
Setup
Keystone
Lens
Lamp Power
Lamp Manangement
Test Pattern
Initial Settings
+0
300
Orientation
1 2
Lamp Mode
Single
Double
Cancel
Confirm
Lamp Selection
2
1
Alt
+
-
Lamp Management
Fig.30
Lamp Power
Lamp Manangement
1
x
Lamp not working
(this symbol appears after a series of
attempted uses are unsuccessful).
Lamp Power
Lamp Manangement
1
Lamps being lit
(this symbol appears when a lamp is
being lit)
Lamp Power
Lamp Manangement
1
Lamps in cooling phase
(this symbol appears when a lamp is
cooling off)
Lamp Power
Lamp Manangement
1
!
Malfunction
A malfunction in indicated in the graphic