114
007-4564-001
4: Troubleshooting and Diagnostics
Troubleshooting
This section covers the following topics:
•
“Environmental Fault Monitoring” on page 114
•
“Bezel LEDs” on page 114
Environmental Fault Monitoring
The workstation monitors its environment to ensure proper operation. It will
automatically power off if any of the following faults are found:
•
Any fan spins at less than 80% of nominal speed.
•
Any temperature sensor registers 158
°
F (70
°
C) or above.
•
Any voltage r/- 20% of nominal.
If your workstation is powering off unexpectedly, check for these conditions.
Bezel LEDs
The LEDs in the workstation bezel can provide important troubleshooting information.
Table 4-1 shows a list of LED signals and what they mean.
Table 4-1
Bezel LED Signals
LED Signal
Explanation
Blinking White
Power button pressed (On or Off)
Solid white
Successful PROM boot/ OS running
Solid yellow
L1 has detected a problem. Check the L1
display for more information
Blinking red
General system failure
Check the L1 display for more information
Solid red
System node board failure
(failed to read PROM at power on)
Summary of Contents for Tezro
Page 3: ...007 4564 001 iii Record of Revision Version Description 001 July 2003 Original Publication ...
Page 4: ......
Page 9: ...Contents 007 4564 001 ix Lithium Battery Compliance Statement 147 Index 149 ...
Page 10: ......
Page 14: ......
Page 16: ......
Page 22: ......
Page 42: ...20 007 4564 001 1 Installation and Operation Procedures Figure 1 20 Restart Notifier ...
Page 44: ......
Page 68: ......
Page 81: ...Returning the Workstation to Service 007 4564 001 59 Figure 3 5 Installing the Bezel A B C D ...
Page 134: ......
Page 146: ......