Diagnostics
007-4564-001
117
Offline Diagnostics
Offline diagnostics run a sequence of tests on the system hardware under a standalone
diagnostic environment; the operating system cannot be running while the offline
diagnostics test the system
The offline diagnostics include a “launcher” that automatically runs a sequence of tests.
In most cases, you should run the offline diagnostics automatically with the launcher.
Use the following procedure to run the launcher:
1.
Power on the system.
2. Wait until the
System Maintenance
menu appears.
Note:
If the
Autoload
PROM variable is set to
Yes
, you must click on the
Stop for
Maintenance
button to access the
System Maintenance
menu.
3. Select the
Run Diagnostics
option.
Note:
You can also start the launcher by entering the following command at the
command monitor (PROM) prompt (>>)
:
boot -f dksc (0,1,0) /stand/smdk/smdk --a
The launcher automatically runs the offline diagnostics on system components in the
following order:
•
CPU
Note:
The CPU test supports single-CPU systems; if a system has more than one
CPU, the CPU test does not run.
•
Secondary cache
•
Memory DIMMs
•
I/O components: IO9 card and audio and I/O daughtercard (including the SCSI
controller, serial ports, Ethernet port, mouse port, keyboard port, and RTO/RTI
connectors)
Summary of Contents for Tezro
Page 3: ...007 4564 001 iii Record of Revision Version Description 001 July 2003 Original Publication ...
Page 4: ......
Page 9: ...Contents 007 4564 001 ix Lithium Battery Compliance Statement 147 Index 149 ...
Page 10: ......
Page 14: ......
Page 16: ......
Page 22: ......
Page 42: ...20 007 4564 001 1 Installation and Operation Procedures Figure 1 20 Restart Notifier ...
Page 44: ......
Page 68: ......
Page 81: ...Returning the Workstation to Service 007 4564 001 59 Figure 3 5 Installing the Bezel A B C D ...
Page 134: ......
Page 146: ......