![Silex technology MNS-300EM Command Manual Download Page 54](http://html1.mh-extra.com/html/silex-technology/mns-300em/mns-300em_command-manual_1271326054.webp)
42
MNS-300EM Command Manual
Sets the Mesh encryption key to Mesh profile of the specified number [profile_num].
SET MEsh [profile_num] KEY <key>
Specify the Mesh encryption key for <key>.
The factory default value is
silex technology, Inc
.
SH MEsh [profile_num] KEY
can show the current value.
Example:
Local> SET MESH 1 KEY mesh-key01
Sets the maximum number of hops to Mesh profile of the specified number [profile_num].
SET MEsh [profile_num] HOP <n>
Enter the following value for <n>.
1-5
: Changes the hop limit to the specified amount.
NOlimit
: Removes the upper hop limit.
The factory default value is
NOlimit
.
S
H MEsh [profile_num] HOP
can show the current value.
5-8. SET MEsh [profile_num] KEY
5-9. SET MEsh [profile_num] HOP
Summary of Contents for MNS-300EM
Page 1: ...MNS 300EM Command Manual...
Page 2: ...Copyright 2019 silex technology Inc All rights reserved WA105840XB...
Page 13: ...1 Introduction 1 1 Introduction Thank you for purchasing the Intelligent Module MNS 300EM...
Page 18: ...6 MNS 300EM Command Manual Blank page...
Page 19: ...3 Network Commands 7 3 Network Commands This chapter describes the network parameter commands...
Page 60: ...48 MNS 300EM Command Manual...
Page 106: ...94 MNS 300EM Command Manual Blank page...
Page 110: ...98 MNS 300EM Command Manual Blank page...
Page 111: ...12 NTP Commands 99 12 NTP Commands This chapter describes the commands for NTP settings...
Page 122: ...110 MNS 300EM Command Manual Blank page...
Page 126: ...114 MNS 300EM Command Manual Blank page...
Page 131: ...17 Other Commands 119 17 Other Commands This chapter describes other commands...