COPYRIGHT SERENYA 

COD. 2001 

SERENYA 

by Silentron

 – made in Italy

 

Supplementary keypads:

 enter the numerical code and then press the green key 

Key-fobs

:

 

press the green key 

  

Attention!

 disarming is always full unless the remote controls and keypads are programmed otherwise 

– If some zones are required to remain 

active, they must be armed after disarming has been performed. 
 

INFORMATIONS

:

 

after every arming and disarming it is possible to have clear vocal information regarding events that have occurred.  

Attention: if the volume is zero we’ll have: 

Low battery/ies

: series of successive beeps and indication on the control panel display ;  

Doors/windows left open

: series of successive beeps and indication on the control panel display. The control panel is armed in any case, also 

if left open; in case they’ll be closed after arming they’ll be automatically protected: the next opening will give an alarm. 
 

3.2.3)  DISARMING  UNDER  THREAT  (ANTI-COERCION):

 

Attention!

  To  disarm  the  control  panel  using  a  code  programmed  as  ANTI-

COERCION the operation is the same, but the telephone transmitter will be silently activated calling the envisioned USERS. 
 

3.2.4) 

CONTROL PANEL TEST - BATTERY REPLACEMENT 

There are 3 types of test: CONTROL UNIT (DETECTORS) - DIALLER - FIELD METER. The access to the TEST is also useful for changing the 
batteries because in TEST mode the sirens are blocked, therefore there will be no tampering alarm. 
Attention: once replaced the control panel battery it will be necessary to re-program date and time. 
 

A) CONTROL PANEL TEST (empty list)

 : test  key-fobs and alarm of every detector, always waiting 10 seconds between one alarm and the other, up 

to 50 successive alarms, which remain memorised. If there are several detectors, perform the test in two stages. At the end check the correct 
reception of every alarm, checking on the display by means of the arrows  

 

 : 

13 / 02 / 09               17,00 

 

DISARMED         _  ▄  █ 

         Enter USER code 

 

 

 

  TEST 
 

CONTROL PANEL             ↓↑ 

 

EMPTY LIST 

 

TEST 

 

 

 

Test key-fobs: press the green button 
Remark: some key-fobs work on one 

frequency 

  DISARMED   (name) 
 
  01    C1   H,    C2   _     ↓↑ 

The green button function is the disarming 

Name: it will appear the name to which the key-fob is associated.  

01: It’s the first of the 50 possible tests 

C1 and C2 identify the received signal level (no indication = zero) 

Remote keypad test: enter the 5 digits 

code and press the red button 

  ARMED         (name) 
 
  02    C1   H,    C2   M     ↓↑ 

The red button function is the total arming 

Name: it will appear the name to which the code is associated.  

02: It’s the second of the 50 possible tests 

C1 and C2 identify the received signal level (no indication = zero) 

Detectors test (look remark) simulate 
an alarm condition for every detector 

individually 

  ALARM         (det. name.)     
 
  03    C1   H,    C2   H     ↓↑ 

ALARM is the alarm transmission (TAMPER in case of tempering)  

A01 is the detector identification if a name hasn’t been associated to.  

The other indications are the same of before 

 

The quality of the radio signal is described as follows: H = high ; M = medium; L = low.  
In all these cases the system functions correctly: differences in signal are due to distance and physical obstacles between the control unit and 
that detector. If there is no indication for one of the frequencies, it is probable that the detector is beyond maximum range or that there are 
interferences on that frequency. If there are no indications of either frequency, perform a real test; i.e. the control unit and cause an alarm. Since 
the TEST signal is attenuated in accordance with Standard EN50131, the device may be functioning correctly after all: if no alarm occurs, call 
for after-sales technical assistance. 
 
RADIO RANGE (look at the glossary): If we don’t obtain an alarm we need to move the detector somewhere else or buy a repeiter Cod. 2009.   

 
Attention!

 Some detectors transmit the alarm twice: two consecutive signals could occur. 

Attention!

 It is possible that a detector signal is sometimes H (M-L), sometimes M (H-L): this is due to occasional interference or the movement 

of persons in the protected rooms during the tests. This occurs often when checking the remote controls, since the position of the remote control 
in relation to the control unit is not permanent and therefore, the signal received tends to vary. 

Attention!

 To perform a TEST of the volumetric detectors, no one should be in the protected area for at least three minutes prior to the test, 

which is performed by crossing this area: the detector light indicates the alarm, which will be memorised in the control unit. 

Attention!

 Do not forget open protected doors/windows after TEST because during the first successive arming there will be no relative signal. 

 

B) RADIO RECEPTION TEST 

– INTEGRATED FIELD METER 

Ce  test  permet  d'évaluer  mieux  la  réception  d'un  unique  signal  radio,  donc  il  aide  à  trouver  la  meilleure  situation  de  positionnement  du 
transmetteur dans le cas de portée insuffisant. 

 

13 / 02 / 09               17,00 

 

DISARMED           _  ▄  █ 

          Enter USER code 

 

 

 

  TEST 
   
CONTROL PANEL            ↓↑ 

 

 

 

  TEST 
 
FIELD

 

METER

               

       ↓↑ 

  

 

During an alarm transmission the 

specific signal level and/or the 

possible noise is visualized 

  C 1 :  █ █ █ █ █ █ 
  C 2 :  █ █ █ █ █ █ █ █ 

The level is indicated by 8 signs. 

During the Test the sensitivity of the receiver is reduced, as request by the 

European rules: this means that also a low signal level during test can be enaugh 

 

Summary of Contents for SERENYA 2000

Page 1: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy SERENYA MIX GSM cod 2001 Mixed wired wireless control panel with GSM telephone transmitter ...

Page 2: ...tions It is mandatory to dispose of accumulators waste batteries according to the Standards in force This is also the case when the devices must be scrapped The batteries must be previously removed returning them to the seller or depositing them in the relevant containers made available by the distribution network If liquid should escape from the batteries use silicone gloves to protect the hands ...

Page 3: ... 1 2 ARMING DISARMING DEVICES it s possible to program up to 10 key fobs and an unlimited number of keypads look Warning SERENYA control panels can be commanded trought the on board keypad or trought bidirectional key fobs Code 2023 and or trought bidirectional keypads Code 2028 qui confirment les opérations effectuées Soit les télécommandes que les claviers disposent de touches fonction pour acti...

Page 4: ...en a transmitter detectors key fobs keypadss and a receiver control panel sirens In our case because of the low transmission power imposed by the Rules the radio range can change a lot especially inside environments where the position of the transmitter in relation to the receiver is basical Besides walls and furniture sometimes create reflections of the radio signals increasing or reducing the ra...

Page 5: ...y arming 2 2 Bidirectional telephone part Telephone calls In the installation phase the relevant messages must be recorded written and connected to telephone numbers to call in the event of alarms for example the ALARM will be connected to user family or friend s numbers numbers of intervention forces It is useless to connect the installer s number to the alarm calls while it is useful to connect ...

Page 6: ... generating a Tamper alarm disconnect and connect again power supply and begin entering the factory code this operation doesn t delete the realized programming a INSTALLER CODE from 4 to 8 digits which allows access to all programming but not operations b USER CODE from 4 to 8 digits it allows the followings functions placing the control unit in TEST mode for testing or battery change reading the ...

Page 7: ...ssible tests C1 and C2 identify the received signal level no indication zero Detectors test look remark simulate an alarm condition for every detector individually ALARM det name 03 C1 H C2 H ALARM is the alarm transmission TAMPER in case of tempering A01 is the detector identification if a name hasn t been associated to The other indications are the same of before The quality of the radio signal ...

Page 8: ...all done KO failed call OC line busy NO no answer READING THE EVENTS WITH CONTROL MANAGEMENT 13 02 09 10 10 INSTAL Date and time of the event INSTAL installer access USAGER USER access GSM no GSM field NUM MOD telephone number changement GSM TEST automatic Restart operation of the GSM module READING THE ALARMS 13 02 09 10 10 ARMED JOHN Date and time of the event ARM total arming ARM AB armed parti...

Page 9: ...ll press ESC or the button 3 3 10 OTHER FUNCTIONS OF THE CONTROL PANEL Control units with a GSM module offer other automatic functions which can be programmed during installation periodic transmission of control unit operational status SMS GSM models only communication of SIM expiry it is recommended to use SIM without expiry SMS notification of failure and reinstatement of electrical mains power ...

Page 10: ...ADD NAME PHILIP PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CANC or modify the association numbers messages Using buttons from 1 to 6 PHONE BOOK CONFIRM MEMORY CONFIRM 01 SEARCH POSIT CONFIRM ADD POSITION 01 PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CA...

Page 11: ...te it only to the number of the interested doctor MSG 5 Attention technical problem at M Rossi s house via Bianchi 10 Turin it will be added fire detector flooding or other depending by the association MSG 6 Attention message from M Rossi s house via Bianchi 10 Turin change the battery the name of the device will be added it will be control panel for the battery of the control panel 4 6 2 VOCAL ME...

Page 12: ...itions Use 1 2 3 4 5 6 to modify the managed partitions ENTER CODE 4 5 6 7 8 example Enter a 5 digits code 45678 ON A B C MEMOR OFF A B C LABEL CODE 01 _ _ _ _ _ _ _ _ _ _ _ _ _ Write the name of the CODE owner UNDER THREAT N CONFIRM Enable the UNDER THREAT function for the code Y yes or N no VOCAL LABEL TO RECORD Talk close to the microphone Press for all the recording time Verify the remaining t...

Page 13: ...ways shows the first free position Selecting a previous position the already programmed devices will appear Confirm the one to be modified and procede or delete pressing CANC and re program it 4 9 SETTINGS in this section we can program certain particular functions of the control panel Scroll the different functions using buttons 4 9 1 DETECTOR EXCLUSION EXCL SENSORS CONFIRM A 01 KITCHEN CONFIRM S...

Page 14: ...tore a missing code cut power supply open the unit tampering alarm and disconnect battery Replace after 10 sec and enter the factory code 0 0 0 0 4 9 9 ANTISCANNER the control unit checks the radio signals in the ether and signals those which interfere with functioning It is possible to set the time of the interference that can be ignored in seconds 1 60 exceeding which the siren is triggered in t...

Page 15: ...4 9 16 FW VERSION display of the control unit version for any interventions FW VERSION CONFIRM FW VERSION 30155 4 9 17 SYSTEM RESET Confirmation of CANCEL results in the erasing of all the programming performed and of the events memory Be careful before confirming this operation which is irreversible SYSTEM RESET CONFIRM DELETE CONFIRM 4 10 PROGRAMMING THE ALARM DEVICES WIRELESS WARNINGS look spec...

Page 16: ...5mA in stand by and no wired connections 125mA with backlighting of the display 500mA in alarm Autonomy approx 36 hours with charged battery in stand by and without wired connections To determine the autonomy in the presence of wired connections measure the absorption of the battery without 230V and calculate it correctly Alarm inputs up to 50 instant programmable detectors delayed or AND on 3 arm...

Page 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Page 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Page 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...

Page 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Reviews: