background image

 

COPYRIGHT SERENYA 

COD. 2001 

SERENYA 

by Silentron

 – made in Italy

 

Identification:

 the correct vocal recording and writing of the "labels" of the various detectors in the programming phase allows the user to 

receive all messages with the exact indication regarding the device of interest.  

 
2.2.3) HOME AUTOMATION FUNCTIONS  
A) Programmable clock:

 

the control unit has a programmable clock for forced arming (voir 3.2.6)  

B) Radio Outputs:

 16 radio commands are available to command local radio switches, to be activated via telephone calling the control panel to 

switch-on lights or other electrical charges. These receivers can also be activated via key-fobs, keypads, detectors (look 3.3 and followings) 
 
 

2.3) FUNCTIONING OF THE SIRENS - ALSO SEE SPECIFIC MANUAL 

The control panels control the indoor and outdoor radio sirens: 

a) Indoor sirens:

 they emit an arming (partial/full 3 Beeps) and disarming (just one Beep) acoustic signal, the intensity of which can be 

regulated to zero. The signal is set off for 3 minutes in the case of a general, tamper or panic alarm. 

b) Outdoor sirens:

 they emit an arming (partial/full 3 Beeps) and disarming (just one Beep) acoustic signal, the intensity of which can be 

regulated to zero and they flash at the same time. The sirens activate for 3 minutes in the case of a general, tampering or panic alarm after a 
pre-alarm period of about 10 seconds, during which an intermittent acoustic signal is emitted. This delay, which cannot be changed, is intended 
to prevent disturbance if one forgets to disarm the system. In the case of EXTERNAL ALARM programming the outdoor sirens are not triggered, 
but the pre-alarm condition continues for up to 3 minutes or a recorder dissuasive message is played (code 2032). 
 

3) THIRD PART 

– CONTROL PANEL FUNCTIONING 

 

3.1) SECURITY PROTECTION 

– USER CODE – INSTALLER CODE 

The control unit is provided with a factory 

code “0 0 0 0” which allows access to the programming procedure. During installation it is necessary 

to change this code, programming other two ones (differents between them): USER code and INSTALLER code. 
In case of lost or forgotten codes the only solution consists in open the control panel generating a Tamper alarm, disconnect and connect again 
power supply and begin entering the factory code: this operation doesn’t delete the realized programming. 
 

a) INSTALLER CODE:

 from 4 to 8 digits, which allows access to all programming but not operations. 

 

b) USER CODE:

 from 4 to 8 digits, it allows the followings functions 

  placing the control unit in TEST mode for testing or battery change. 

  reading the EVENTS MEMORY 

  programming/modification of listed telephone numbers (see third part) 

  recording/modification of all vocal messages (see third part) 

  addition/deletion of remote controls and/or numeric arming/disarming codes (see third part) 

  modification of supplementary wired key function (see third part) 

  modification of certain SETTINGS: Exclusion of radio or wired detectors (sensors) 

– Clock/date setting – Change of user code – Change of    

daylight-saving time 

– Change of display back-lighting – Regulation of vocal message volume - Change of automatic forced arming – Control 

unit firmware version check 
 

 

Attention!

 Careless with the USER code can limit the efficiency of the entire system, therefore, it is advisable to be informed on the various 

functions before making any changes. 

 

3.2) USER’s OPERATIONS – 

NORMAL SITUATION OF THE CONTROL PANEL 

 

13 / 02 / 09               17,00 

 

DISARMED          _  ▄  █  █ 

  DATE                   TIME 
 
  STATUS     GSM SIGNAL 

 

Date and time must be correctly programmed and upgraded at least every 6 months 

(maintenance): look at the SETTINGS menù 

 

3.2.1) ARMING - DISARMING USING THE CONTROL UNIT KEYPAD 

(VISUAL, VOCAL CONFIRM) 

 

 
 

3.2.2) OPERATIONS WITH REMOTE CONTROLS AND/OR ADDITIONAL KEYPADS 
 
TOTAL ARMING  
Supplementary keypads:

 enter the numerical code and then press the red key 

KEY-FOBS:

 press the red key 

 
PARTIAL ARMING

 (vocal confirm or a long Beep) 

Supplementary keypads:

 enter the numerical code, by pressing A, B, C exclude the zones that are not to be armed and then press the red key 

KEY-FOBS:

 press the white key to arm zones A+B (for other solutions see the remote control instructions) 

 

DISARMING

  

13 / 02 / 09               17,00 

 

  DISARMED        _  ▄  █ 

Arming :enter the 5 digits code and 

press the button 

 

 

 

 

ARM GROUPS : 

A   B   C 

Select partitions to don’t arm using 

the buttons 1,2,3 and press the button 

 

 

 

 

 

 

13 / 02 / 09               17,00 

 

  ARMED     A B C  _  ▄  █ 

Disarming : enter the 5 digits code 

and press the button 

 

 

 

 

13 / 02 / 09               17,00 

 

  DISARMED         _  ▄  █ 

The control panel confirms the operations.  

If new events are happened a vocal 

message infor the USER 

Summary of Contents for SERENYA 2000

Page 1: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy SERENYA MIX GSM cod 2001 Mixed wired wireless control panel with GSM telephone transmitter ...

Page 2: ...tions It is mandatory to dispose of accumulators waste batteries according to the Standards in force This is also the case when the devices must be scrapped The batteries must be previously removed returning them to the seller or depositing them in the relevant containers made available by the distribution network If liquid should escape from the batteries use silicone gloves to protect the hands ...

Page 3: ... 1 2 ARMING DISARMING DEVICES it s possible to program up to 10 key fobs and an unlimited number of keypads look Warning SERENYA control panels can be commanded trought the on board keypad or trought bidirectional key fobs Code 2023 and or trought bidirectional keypads Code 2028 qui confirment les opérations effectuées Soit les télécommandes que les claviers disposent de touches fonction pour acti...

Page 4: ...en a transmitter detectors key fobs keypadss and a receiver control panel sirens In our case because of the low transmission power imposed by the Rules the radio range can change a lot especially inside environments where the position of the transmitter in relation to the receiver is basical Besides walls and furniture sometimes create reflections of the radio signals increasing or reducing the ra...

Page 5: ...y arming 2 2 Bidirectional telephone part Telephone calls In the installation phase the relevant messages must be recorded written and connected to telephone numbers to call in the event of alarms for example the ALARM will be connected to user family or friend s numbers numbers of intervention forces It is useless to connect the installer s number to the alarm calls while it is useful to connect ...

Page 6: ... generating a Tamper alarm disconnect and connect again power supply and begin entering the factory code this operation doesn t delete the realized programming a INSTALLER CODE from 4 to 8 digits which allows access to all programming but not operations b USER CODE from 4 to 8 digits it allows the followings functions placing the control unit in TEST mode for testing or battery change reading the ...

Page 7: ...ssible tests C1 and C2 identify the received signal level no indication zero Detectors test look remark simulate an alarm condition for every detector individually ALARM det name 03 C1 H C2 H ALARM is the alarm transmission TAMPER in case of tempering A01 is the detector identification if a name hasn t been associated to The other indications are the same of before The quality of the radio signal ...

Page 8: ...all done KO failed call OC line busy NO no answer READING THE EVENTS WITH CONTROL MANAGEMENT 13 02 09 10 10 INSTAL Date and time of the event INSTAL installer access USAGER USER access GSM no GSM field NUM MOD telephone number changement GSM TEST automatic Restart operation of the GSM module READING THE ALARMS 13 02 09 10 10 ARMED JOHN Date and time of the event ARM total arming ARM AB armed parti...

Page 9: ...ll press ESC or the button 3 3 10 OTHER FUNCTIONS OF THE CONTROL PANEL Control units with a GSM module offer other automatic functions which can be programmed during installation periodic transmission of control unit operational status SMS GSM models only communication of SIM expiry it is recommended to use SIM without expiry SMS notification of failure and reinstatement of electrical mains power ...

Page 10: ...ADD NAME PHILIP PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CANC or modify the association numbers messages Using buttons from 1 to 6 PHONE BOOK CONFIRM MEMORY CONFIRM 01 SEARCH POSIT CONFIRM ADD POSITION 01 PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CA...

Page 11: ...te it only to the number of the interested doctor MSG 5 Attention technical problem at M Rossi s house via Bianchi 10 Turin it will be added fire detector flooding or other depending by the association MSG 6 Attention message from M Rossi s house via Bianchi 10 Turin change the battery the name of the device will be added it will be control panel for the battery of the control panel 4 6 2 VOCAL ME...

Page 12: ...itions Use 1 2 3 4 5 6 to modify the managed partitions ENTER CODE 4 5 6 7 8 example Enter a 5 digits code 45678 ON A B C MEMOR OFF A B C LABEL CODE 01 _ _ _ _ _ _ _ _ _ _ _ _ _ Write the name of the CODE owner UNDER THREAT N CONFIRM Enable the UNDER THREAT function for the code Y yes or N no VOCAL LABEL TO RECORD Talk close to the microphone Press for all the recording time Verify the remaining t...

Page 13: ...ways shows the first free position Selecting a previous position the already programmed devices will appear Confirm the one to be modified and procede or delete pressing CANC and re program it 4 9 SETTINGS in this section we can program certain particular functions of the control panel Scroll the different functions using buttons 4 9 1 DETECTOR EXCLUSION EXCL SENSORS CONFIRM A 01 KITCHEN CONFIRM S...

Page 14: ...tore a missing code cut power supply open the unit tampering alarm and disconnect battery Replace after 10 sec and enter the factory code 0 0 0 0 4 9 9 ANTISCANNER the control unit checks the radio signals in the ether and signals those which interfere with functioning It is possible to set the time of the interference that can be ignored in seconds 1 60 exceeding which the siren is triggered in t...

Page 15: ...4 9 16 FW VERSION display of the control unit version for any interventions FW VERSION CONFIRM FW VERSION 30155 4 9 17 SYSTEM RESET Confirmation of CANCEL results in the erasing of all the programming performed and of the events memory Be careful before confirming this operation which is irreversible SYSTEM RESET CONFIRM DELETE CONFIRM 4 10 PROGRAMMING THE ALARM DEVICES WIRELESS WARNINGS look spec...

Page 16: ...5mA in stand by and no wired connections 125mA with backlighting of the display 500mA in alarm Autonomy approx 36 hours with charged battery in stand by and without wired connections To determine the autonomy in the presence of wired connections measure the absorption of the battery without 230V and calculate it correctly Alarm inputs up to 50 instant programmable detectors delayed or AND on 3 arm...

Page 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Page 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Page 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...

Page 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Reviews: