COPYRIGHT SERENYA
COD. 2001
SERENYA
by Silentron
– made in Italy
MAINS FAILURE
CONFIRM
MAINS FAILURE N
T : 30 min.
Activate the function changing N
(no) in Y (yes) using the buttons ↑↓.
Insert the delay after which we
wanna have the message
MAINS FAILURE Y
T : 05 min:
4.9.4) PERIODIC CALL:
follow the vocal instructions for the SMS
– look also 2.2.2
PERIODIC CALL
CONFIRM
PERIODIC CALL N
T : 24 h 00 :00
Enable the function changing N (no)
in Y (yes) using the buttons ↑↓.
Insert the delay after which we
wanna have the message (hours)
PERIODIC CALL Y
T : 24 H 10.00
4.9.5) SIM VALIDITY:
follow the vocal instructions for the SMS
– look also 2.2.2
SIM VALIDITY
CONFIRM
SIM VALIDITY N
T : 11 month
Enable the function changing N (no)
in Y (yes) using the buttons ↑↓.
Insert the delay after which we
wanna have the message (hours)
SIM VALIDITY Y
T : 10 month
4.9.6) TIME/DATE:
updating the internal clock and date is important for the historic memory of the events. Internal clock - precision: the adopted
technical solutions may cause a flexibility up to 2 seconds per day, which should be adjusted during the system periodical check, at least every
6 months.
TIME AND DATE
CONFIRM
SET TIME
19.25
SET DATE
DD / MM / YY
4.9.7) TELEPHONE EXCHANGE (PABX):
function not present.
4.9.8) INSTALLER CODE
:
useful function for seeing/changing this code
INSTALLER CODE
CONFIRM
INSTALLER CODE
2222
Press
← ← ← ← to cancel the code and enter the new
Warning: to restore a missing code, cut power supply, open the unit
(tampering alarm) and disconnect battery. Replace after 10 sec. and
enter the factory code 0 0 0 0.
4.9.9) ANTISCANNER
: the control unit checks the radio signals in the ether and signals those which interfere with functioning. It is possible to
set the time of the interference that can be ignored in seconds (1-60), exceeding which the siren is triggered in the control unit and current is
found at the SIR terminals.
Attention !
Reduced time get faster communication of radio interference, that can depends by Tamper attempts or occasional interference in
the ether,
and so that to don’t care: for this reason the control panel will present a pre-programmed time of 60 secondes, a right delay for the
function target.
ANTISCANNER
CONFIRM
ANTISCANNER N
T: 60 SEC.
Choose Y (yes) or N (no) to set the
function and write timing of
signalled noises 1-99 sec.
ANTISCANNER Y
T: 90 SEC.
4.9.10)
SUPERVISION
: supervision is the transmission of the operating status that every peripheral device transmits approx. every 40 minutes:
the absence of 8 consecutive signals (over 5 hours) from a peripheral device causes the signal of the phenomenon with every arming/disarming
of the system. Such communication identify the necessity of a functionality control of the device (TEST).
SUPERVISION
CONFIRM
SUPERVISION N
CONFIRM
Choose Y (yes) or N (no)
to set the function
4.9.11)
EXIT TIME
: Attention! Times too short do not allow service communications that take place during this time, for this reason we suggest
to program at least 60 seconds, as the device automatically propose.
Summary of Contents for SERENYA 2000
Page 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...
Page 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...
Page 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...
Page 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...