4.8.2) INTRUSION AND 24 HOURS ALARM GROUPS  

– KEYPADS AND BIDIRECTIONAL SIRENS TAMPERS 

 

REMOTE CONTROL            

 

   

CONFIRM                         

 

 

 

 

 

 

ALARM GROUP  A      

 

   

CONFIRM             

    

 

 

     

ALARM GROUP  A            

    

  

  OUTDOOR ALARM   N   

      

Confirm (

) if we don’t want to 

configure the partition as Outdoor 

alarm. Press 

 to change N (no) to Y 

(yes) = outdoor alarm

 

 

SENSOR        A01     

 

        

CONFIRM      

 

 

 

       SENSOR           A01 
  DELAY   N    AND   N 

Press 

 in case of Entry delay and AND  function not necessary 

Press 1 

  for DELAY and enter the entry time in seconds  

Press 2 for AND : we’ve to program 2 detectors 

 

     

SENSOR             A01 

     INSERT BATTERY

 

     
  SENSOR                 A01 
  

 DELAY              0 SEC 

                  (Y)               (Y)

 

 

LABEL                       A01 

       CUISINE (exemple) 

Write an 8 digits name. Clear to well 

identify the detector 

 

   VOCAL LABEL 

                   

TO RECORD

 

 

 

Talk close to the microphone. 

Press 

 

for all the recording 

time. Verify the remaining 

time (total 240 seconds)

 

 

       RECORDING 

   228 . 227 . 226 . 225 . . .     

     

After recording automatic listening.  

Press ESC to exit, 

 to listen again 

or CANC to delete and restart

 

ALARM GROUP  A            

 

   

CONFIRM                      

  

 

 

 

      ALARM GROUP  A     

  

 

  OUTDOOR ALARM  N 

     

 

 

SENSOR                  A02

 

   

 

        

CONFIRM               

 

 

Continue as above with the detectors 

of the partition A. To change 

partition use 



  

at the beginning of the specific menu

 

 

TO MODIFY AND DELETE PROGRAMMED DEVICES:  

Entering into the EXTRAS menu and confirming a partition the control panel always shows the first free position.  
Selecting a previous position (↓↑) the already programmed devices will appear. Confirm the one to be modified and procede, or delete pressing 
CANC and re-program it. 

 

4.9) SETTINGS:

 in this section we can program certain particular functions of the control panel. Scroll the different functions using buttons 

 

  

 

4.9.1) ) DETECTOR EXCLUSION 

 

       EXCL. SENSORS     

 

  

  

CONFIRM

                  

     

 

 

     A 01  

KITCHEN     

       

 

   

   

CONFIRM

                  

     

Select the detector you want 

to exclude pressing  



  

 

 

 Select (



) INCLUD or  

 EXCLUD  and confirm 

    

 The excluded sensors will  
 not give any alarm. 

 

4.9.2) RADIO COMMANDS:

 calling the control panel via telephone we can activate functions. Control panels have 16 possibles radio 

commands to locally activate receivers RX,

 

whom on their turn can activate some functions as the lighting activation and to command home 

automation devices in the local area. To be commanded by the control panel these receivers must memorize at least one of the RADIO 
COMMANDS mentioned here following.  

Attention!

 When we press 

 to program the radio switch, it has to be ready for programming (look the specific instructions of the device). 

 

 

RADIO OUTPUT       

 

  

  

CONFIRM

                 

     

 

 

RADIO OUTPUT 1    

 

  

CONFIRM      

        

 

 

RADIO OUTPUT  1   

 

 

  

ON – OFF         

    

       

Confirm the command as ON-OFF 

or change it as IMPULSIVE (



Set the receiver and press 

 to 

program it 

ES

RADIO OUTPUT 1    

 

  

CONFIRM     

        

 

 

 

 

        RADIO OUTPUT 2  

 

  

CONFIRM     

         

 

 

Continue in the same way up to 16 available radio commands. 

 

 
4.9.3) MAIN POWER FAILURE:

 follow the vocal instructions for the SMS 

– look also 2.2.2 

 

Summary of Contents for SERENYA 2000

Page 1: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy SERENYA MIX GSM cod 2001 Mixed wired wireless control panel with GSM telephone transmitter ...

Page 2: ...tions It is mandatory to dispose of accumulators waste batteries according to the Standards in force This is also the case when the devices must be scrapped The batteries must be previously removed returning them to the seller or depositing them in the relevant containers made available by the distribution network If liquid should escape from the batteries use silicone gloves to protect the hands ...

Page 3: ... 1 2 ARMING DISARMING DEVICES it s possible to program up to 10 key fobs and an unlimited number of keypads look Warning SERENYA control panels can be commanded trought the on board keypad or trought bidirectional key fobs Code 2023 and or trought bidirectional keypads Code 2028 qui confirment les opérations effectuées Soit les télécommandes que les claviers disposent de touches fonction pour acti...

Page 4: ...en a transmitter detectors key fobs keypadss and a receiver control panel sirens In our case because of the low transmission power imposed by the Rules the radio range can change a lot especially inside environments where the position of the transmitter in relation to the receiver is basical Besides walls and furniture sometimes create reflections of the radio signals increasing or reducing the ra...

Page 5: ...y arming 2 2 Bidirectional telephone part Telephone calls In the installation phase the relevant messages must be recorded written and connected to telephone numbers to call in the event of alarms for example the ALARM will be connected to user family or friend s numbers numbers of intervention forces It is useless to connect the installer s number to the alarm calls while it is useful to connect ...

Page 6: ... generating a Tamper alarm disconnect and connect again power supply and begin entering the factory code this operation doesn t delete the realized programming a INSTALLER CODE from 4 to 8 digits which allows access to all programming but not operations b USER CODE from 4 to 8 digits it allows the followings functions placing the control unit in TEST mode for testing or battery change reading the ...

Page 7: ...ssible tests C1 and C2 identify the received signal level no indication zero Detectors test look remark simulate an alarm condition for every detector individually ALARM det name 03 C1 H C2 H ALARM is the alarm transmission TAMPER in case of tempering A01 is the detector identification if a name hasn t been associated to The other indications are the same of before The quality of the radio signal ...

Page 8: ...all done KO failed call OC line busy NO no answer READING THE EVENTS WITH CONTROL MANAGEMENT 13 02 09 10 10 INSTAL Date and time of the event INSTAL installer access USAGER USER access GSM no GSM field NUM MOD telephone number changement GSM TEST automatic Restart operation of the GSM module READING THE ALARMS 13 02 09 10 10 ARMED JOHN Date and time of the event ARM total arming ARM AB armed parti...

Page 9: ...ll press ESC or the button 3 3 10 OTHER FUNCTIONS OF THE CONTROL PANEL Control units with a GSM module offer other automatic functions which can be programmed during installation periodic transmission of control unit operational status SMS GSM models only communication of SIM expiry it is recommended to use SIM without expiry SMS notification of failure and reinstatement of electrical mains power ...

Page 10: ...ADD NAME PHILIP PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CANC or modify the association numbers messages Using buttons from 1 to 6 PHONE BOOK CONFIRM MEMORY CONFIRM 01 SEARCH POSIT CONFIRM ADD POSITION 01 PHILIP 01 555666777888999 Confirm delete CANC or modify selected name and number VOCAL MESSAGES 2 3 6 Confirm delete CA...

Page 11: ...te it only to the number of the interested doctor MSG 5 Attention technical problem at M Rossi s house via Bianchi 10 Turin it will be added fire detector flooding or other depending by the association MSG 6 Attention message from M Rossi s house via Bianchi 10 Turin change the battery the name of the device will be added it will be control panel for the battery of the control panel 4 6 2 VOCAL ME...

Page 12: ...itions Use 1 2 3 4 5 6 to modify the managed partitions ENTER CODE 4 5 6 7 8 example Enter a 5 digits code 45678 ON A B C MEMOR OFF A B C LABEL CODE 01 _ _ _ _ _ _ _ _ _ _ _ _ _ Write the name of the CODE owner UNDER THREAT N CONFIRM Enable the UNDER THREAT function for the code Y yes or N no VOCAL LABEL TO RECORD Talk close to the microphone Press for all the recording time Verify the remaining t...

Page 13: ...ways shows the first free position Selecting a previous position the already programmed devices will appear Confirm the one to be modified and procede or delete pressing CANC and re program it 4 9 SETTINGS in this section we can program certain particular functions of the control panel Scroll the different functions using buttons 4 9 1 DETECTOR EXCLUSION EXCL SENSORS CONFIRM A 01 KITCHEN CONFIRM S...

Page 14: ...tore a missing code cut power supply open the unit tampering alarm and disconnect battery Replace after 10 sec and enter the factory code 0 0 0 0 4 9 9 ANTISCANNER the control unit checks the radio signals in the ether and signals those which interfere with functioning It is possible to set the time of the interference that can be ignored in seconds 1 60 exceeding which the siren is triggered in t...

Page 15: ...4 9 16 FW VERSION display of the control unit version for any interventions FW VERSION CONFIRM FW VERSION 30155 4 9 17 SYSTEM RESET Confirmation of CANCEL results in the erasing of all the programming performed and of the events memory Be careful before confirming this operation which is irreversible SYSTEM RESET CONFIRM DELETE CONFIRM 4 10 PROGRAMMING THE ALARM DEVICES WIRELESS WARNINGS look spec...

Page 16: ...5mA in stand by and no wired connections 125mA with backlighting of the display 500mA in alarm Autonomy approx 36 hours with charged battery in stand by and without wired connections To determine the autonomy in the presence of wired connections measure the absorption of the battery without 230V and calculate it correctly Alarm inputs up to 50 instant programmable detectors delayed or AND on 3 arm...

Page 17: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Page 18: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Page 19: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy NOTE ...

Page 20: ...COPYRIGHT SERENYA COD 2001 SERENYA by Silentron made in Italy ...

Reviews: