![Silca Omnia Operating Manual Download Page 30](http://html.mh-extra.com/html/silca/omnia/omnia_operating-manual_1270927030.webp)
7.5
Checking and calibration
The cutting tool on the machine is the part used to cut the key blanks and should be periodically checked and
replaced, if necessary.
Every time the cutting tool is changed, and during periodical operational tests, check calibration.
The OMNIA key-cutting machine requires two types of calibration:
AXIS
and
DEPTH
.
Fig.36
7.5.1
Axis calibration - carriage for bit, double bit and pump keys
Axis calibration is used to adjust the cutting space on the key.
Axis calibration is fi xed and established when the key-cutting machine is being assembled.
Axis calibration control:
1) Turn off the machine and unplug.
2) Use lever (Q) to lock the right-hand clamp in the horizontal position.
3) Close the 2 clamps with their handles (P) and (P1).
4) Disable the tracer point spring by turning the cam (D1) (chap.7.2).
5) Use the lever (L) to take the stops (Y) against the right-hand side of the tracer point and cutter.
The ideal condition is achieved when the internal part of the left-hand stop is up against the right-hand side of the
tracer point and the internal part of the right-hand stop is in contact with the right-hand side of the cutter.
If this condition is not achieved, contact Silca After-Sales Service.
Fig.37
Operating Manual
OMNIA / OMNIA 650rpm / OMNIA MAX / OMNIA W MAX
Copyright Silca 2014
26