Communication via
CAN bus (CANopen)
MSA501
Date: 12.10.2018
Art. No. 88734
Mod. status 330/18
Page 29 of 51
5.6.2.9
100Ch: Guard Time
Object 100Ch indicates the cycle time set in the master for node guarding (see chapter
). The cycle time is indicated in milliseconds. Value “‘0h’” means that Node
Guarding is deactivated.
Subindex
00h
Description
Guard Time
Access
rw
PDO-Mapping
no
Data type
UNSIGNED 16
Default
0h
EEPROM
yes
5.6.2.10
100Dh: Life Time Factor
Object 100Dh indicates the life time factor set in the master for node guarding (see chapter
). Value “0h’” means that Node Guarding is deactivated.
Subindex
00h
Description
Life Time Factor
Access
rw
PDO-Mapping
no
Data type
UNSIGNED 8
Default
0h
EEPROM
yes
5.6.2.11
1010h: Store Parameter
Parameters are transferred into the EEPROM with this object in order to ensure that they are
protected from loss of voltage. Different parameter groups are stored depending on the
selection of the sub-index to be accessed. The string “save” must also be sent as data
content.
Subindex
00h
Description
indicates the largest supported sub-index
Access
ro
PDO-Mapping
no
Data type
UNSIGNED 8
Default
4h
EEPROM
no