Signamax
™
065-7921PoE 12-Port 10/100/1000BaseT/TX Web Smart PoE Switch
76
4-2-9. Bandwidth Management
Function name:
Bandwidth Management
Function description:
Bandwidth Management function is used to set up the limit of Ingress and Egress
bandwidth for each port.
Note:
Each port of t
he switch
owns
16KB packet buffer. The packet buffer size will be reduced
when the bandwidth rate limitation
is
enabled,
which
may cause that jumbo frame cannot
be forwarded
.
Please avoid enabling jumbo frame and bandwidth rating function
s
at the same time.
Fig. 4-20
Parameter description:
Port Number:
Choose the port that you would like this function to work on it. Valid range of the
port is 1~12. If you would like to set up all ports at a time, user is also allowed to
choose “All” in the selection list to simplify the procedure of configuration.
All Traffic for Ingress Rate Limiting:
Set up the limit of Ingress bandwidth for the port you choose. Incoming traffic will
be discarded if the rate exceeds the value you set up in Data Rate field. Pause
frames are also generated if flow control is enabled. The format of the packet limits
to unicast, broadcast and multicast. Valid range is 0~1000.