Managed Ethernet Switch
User’s Manual 163
2.
Usage:
Use this command to to set time zone.
3.
Command Syntax:
clock timezone TIMEZONE
TIMEZONE Specifies the time zone. (Please refer the Appendix B)
4.
Example:
The following example sets time zone (Canada/Yukon):
switch_a(config)#clock timezone YST9YDT
switch_a(config)#
Polling Interval:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to specify the polling interval.
3.
Command Syntax:
ntp polling-interval MINUTE
MINUTE <1-10080> The polling interval. Enter a value in the range 1 to
10080 minutes.
4.
Example:
The following example specifies the polling interval
60
minutes:
switch_a(config)#ntp polling interval 60
switch_a(config)#
Daylight Saving Mode:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use this command to enable daylight saving.
Use
no clock summer-time
command to disable daylight saving.
3.
Command Syntax:
clock summer-time TIMEZONE weekday WEEK DAY MONTH HOUR
Summary of Contents for 065-7734
Page 1: ...Signamax Connectivity Systems Managed Ethernet Switch Model 065 7734 U S E R S G U I D E ...
Page 35: ...Managed Ethernet Switch User s Manual 34 ARP Table Click ARP Table to view ARP Table ...
Page 53: ...Managed Ethernet Switch User s Manual 52 ...
Page 58: ...Managed Ethernet Switch User s Manual 57 ...
Page 59: ...Managed Ethernet Switch User s Manual 58 ...