Managed Ethernet Switch
User’s Manual 153
switch_a(config-if)#
2.
Usage:
Use this command to set the interval between reauthorization attempts.
Use
no dot1x timeout re-authperiod
command to delete the interval
between reauthorization attempts.
3.
Command Syntax:
dot1x timeout re-authperiod SECS
no dot1x timeout re-authperiod
SECS <1-4294967295> Specify the seconds between reauthorization
attempts. The default time is 3600 seconds.
4.
Example:
The following example specifies to set the interval
25
seconds between
reauthorization attempts:
switch_a(config)#interface fe1
switch_a(config-if)#dot1x timeout re-authperiod 25
switch_a(config-if)#