Managed Ethernet Switch
User’s Manual 143
Cold Start Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server trap-type enable coldStart
command to enable cold start
trap for SNMP.
Use the
no snmp-server trap-type enable coldStart
command to disable
cold start trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable coldStart
4.
Example:
The following example enables cold start trap for SNMP:
switch_a(config)#snmp-server trap-type enable coldStart
switch_a(config)#
Warm Start Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
The
switch_a(config)#
prompt will show on the screen.
switch_a(config)#
2.
Usage:
Use
snmp-server trap-type enable warmStart
command to enable warm
start trap for SNMP.
Use the
no snmp-server trap-type enable warmStart
command to disable
warm start trap for SNMP.
3.
Command Syntax:
(no) snmp-server trap-type enable warmStart
4.
Example:
The following example enables warm start trap for SNMP:
switch_a(config)#snmp-server trap-type enable warmStart
switch_a(config)#
Link Down Trap:
1.
Command Mode: Configure mode
Logon to Configure Mode (Configure Terminal Mode).
Summary of Contents for 065-7734
Page 1: ...Signamax Connectivity Systems Managed Ethernet Switch Model 065 7734 U S E R S G U I D E ...
Page 35: ...Managed Ethernet Switch User s Manual 34 ARP Table Click ARP Table to view ARP Table ...
Page 53: ...Managed Ethernet Switch User s Manual 52 ...
Page 58: ...Managed Ethernet Switch User s Manual 57 ...
Page 59: ...Managed Ethernet Switch User s Manual 58 ...