![SIGMATEK MDD 111-1 Manual Download Page 68](http://html1.mh-extra.com/html/sigmatek/mdd-111-1/mdd-111-1_manual_1268140068.webp)
MDP 102-1
Page 68
29.08.2019
6 Maintenance
The servo drive does not require any maintenance.
Note: Opening the enclosure invalidates the warranty
If the casing is dirty, clean with Isopropanol or similar cleaning agent.
•
Dirt inside the unit must be cleaned by the manufacturer
•
Dirty protective grill (fan) may be cleaned with a dry brush
•
Do not immerse or spray.
6.1 Replace and repair
Repair:
The repair of the servo drive has to be done by the manufacturer.
Replace:
If a component of the servo drive system has to be replaced, notice
following checklist (no special mounting tools are required):
Switch off the main switch of the switchgear cabinet and remove the fuses
supplying the servo drive system
Wait at least 7 minutes after disconnecting the servo drive system from the
mains supply voltage before touching live sections of the equipment (e.g.
contacts) or undoing connections. Capacitors can still have dangerous volt-
ages present up to 7 minutes after switching off the supply voltages. To be
sure, measure the voltage in the DC-link circuit and wait until it has fallen
below 40 V.
During operation, the heat sink of components of the servo drive system
can become hot and may reach temperatures above 80 °C (176 °F). Check
(measure) the heat sink temperature and wait until it has cooled below
40 °C (104 °F) before touching it.
Remove the connectors. Make sure, that the identification is clear, not to
swap the connectors at installation of the replacement.
Summary of Contents for MDD 111-1
Page 4: ...MDP 102 1 Page 4 29 08 2019 1 1 Components of a servo system...
Page 13: ...MDP 102 1 29 08 2019 Page 13 2 6 Nameplate...
Page 27: ...MDP 102 1 29 08 2019 Page 27...
Page 28: ...MDP 102 1 Page 28 29 08 2019 Connector layout of X1 X2 X3 X4 and X6...
Page 48: ...MDP 102 1 Page 48 29 08 2019...
Page 50: ...MDP 102 1 Page 50 29 08 2019...
Page 84: ...MDP 102 1 Page 84 29 08 2019...