![SIGMATEK MDD 111-1 Manual Download Page 39](http://html1.mh-extra.com/html/sigmatek/mdd-111-1/mdd-111-1_manual_1268140039.webp)
MDP 102-1
29.08.2019
Page 39
3.3.10 Holding brake control
tt
tt
tt
tt
Enable
Speed
Setpoint
Host
Speed
Setpoint
internally
Actual
Speed
Enable
internally
Brake
Signal
tt
Brake
Force
tt
tt
Emergency ramp
t
BRon
t
BRoff
Max. 1 sec
Speed threshold
Brake disable delay time
Brake enable delay time
tt
+24V_BR
Min. 0.2 sec
Min. 0.1 sec
The figure above shows the processing of the holding brake.
A standard holding brake with 24 VDC input voltage and maximum 1A can be directly exe-
cuted by the servo drive.
The circuit has a high level of functional safety, but is
not personnel safe
.
Summary of Contents for MDD 111-1